SKU · 0015451

SECOH JDK-S-60 Single Series Blower

Weight5 kg
Dimensions177 × 254 × 176 mm
Your Price · Ex VAT
£135.20 £130.00
£156.00 inc VAT
Estimated Lead time: 3-5 Working Days

Estimate delivery costs

PayPal Pay in 3 Learn Klarna Pay in 30 days Learn

You may also need

SECOH JDK-S-60 Single Series Blower Complete with Cable

The SECOH JDK-S-60 is a linear-diaphragm (electromagnetic oscillation) air blower, designed as a modern, energy-efficient replacement for older EL/LP/HP-60 models.

It is engineered for continuous duty aeration service in wastewater treatment, sewage systems, and other applications where dependable, oil-free air supply is needed.

The JDK models are a direct replacement of the Secoh EL series of blower. They feature up to 30% less energy consumption, as well as being more compact than the EL series.

This model is to be used in the Biosafe/ CLP6 unit, located on the inside of the unit.

Features Benefits
Energy-efficient design

Consumes less power (up to ~30% less than comparable older EL Series)

thanks to reduced Internal friction and optimised electromagnetic drive

Compact, Lightweight construction

Smaller footprint and lower weight (6.5 kg) make it easier to install or retrofit

in constrained plant enclosures

Oil-Free Airflow

No oil lubrication is needed, so the delivered air is clean and free of oil

vapour or contaminants - critical for water/ biozones

Low noise & low vibration

The unit features a built-in muffler chamber and vibration isolation

between motor and pump parts to reduce acoustic disturbance

Pulsation-Free flow

Specially shaped pump chambers and muffling result in a smoother,

steadier airflow, better suited for fine diffuser systems

Robust, weather - resistant housing

The blower is rated as rainproof / weatherproof (but should be

sheltered from direct sun, rain, snow)

Modular Serviceability

Standard spare kits (diaphragms, valve boxes, filters) are available

and easy to replace, minimising downtime

APPLICATIONS

  • Water treatment
  • Ponds & Domestic applications
  • Medical and health technology
  • Aeration of fuel cell stacks
  • Aqua-air-lights and design pillars

Technical:

  • Max Flow: 60 Litres per Minute
  • Optimal Operating Pressure: 0.20 Bar
  • Connector Size: 19mm
  • Sound level (at 1.5m): 38dB
  • Voltage: 230 VAC

Please note: The Secoh S-series air blowers come with a standard EU plug, these can be removed without effecting warranty

TANK SERVICING

Why does my system need serviced?

  • It’s important that your sewage treatment plant or septic tank system is emptied and maintained regularly to continue operating optimally.
  • Poorly performing systems can cause serious health hazards as well as local pollution risks.
  • Recent Building Regulations (Part H 2010 – BS EN 12566) state that regular emptying and maintenance of small sewage treatment plants must be undertaken by the homeowner at least once per year, or as per the manufacturer’s guidelines.
  • As a homeowner, you must also ensure that your system remains in good order and replace it when necessary.
  • We do recommend that you keep a detailed log of when your system is inspected, maintained, emptied or serviced as you may need these details in future.
  • Our treatment plant service includes a full check to ensure everything is in perfect working order.
  • Our team can be reached on helpingyou@kingspan.com or 033 240 6868
  • Current lead time is 7–10 days for service visit

Postcode exclusions apply to AB, BT, DD, EH, FK, G, GY, HS, IM, IV, JE, KA, KW, KY, ML, PA20+ & PH, PO30+, ZE

Product specifications for SECOH JDK-S-60 Single Series Blower
Dimensions (W×L×H)177 × 254 × 176 mm
Empty Weight5 kg
Estimated Lead time: 3-5 Working Days

Important — please read

Please ensure the product you are ordering is the correct size and suitable for the purpose. Special order, bespoke and non-stock tanks are not returnable. If you order a tank and find it is too big, too small, or unsuitable for your requirements, it can be expensive to return. Our cancellation & returns policy explains this in more detail — see Terms & Conditions.

Delivery charges

Our shipping costs cover most of the UK. However, parts of England, the Scottish Highlands and Islands (including areas north of the Glasgow / Edinburgh border), Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs.

  • AB
  • BT
  • CA
  • CT
  • DD
  • DG
  • EH
  • FK
  • G
  • GY
  • IM
  • IV
  • JE
  • KA
  • KW
  • KY
  • LD
  • LL
  • ML
  • PA
  • PH
  • PO 30–41 Isle of Wight
  • SA
  • SY
  • TD
  • TN
  • TR
  • ZE
  • Southern Ireland

Looking to avoid shipping charges?

All our tanks are available for collection ex works. Our suppliers are based all over the UK — please call if you wish to collect.

Overseas orders

International orders are welcome. Payment is by IBAN / SWIFT / BIC, MoneyGram and letters of credit. We regret that credit cards are not accepted for international orders.

A purchase order is required; we will then create a pro-forma invoice, and tanks are ordered on clearance of funds.

If you require additional export documentation — for example a Certificate of Origin, or commercial invoices certified by the Chamber of Commerce — you must notify us before completion of your order, as we will have to invoice cost and admin charges to the order.

Please call if you have any questions: +44 (0)1643 703358

Offloading

Unless a HIAB delivery has been booked at additional cost, it is the customer’s responsibility to offload with suitable equipment on the day of delivery. A failed delivery may result in additional charges.

We recommend that installers, plant hire and installation materials — excavators, aggregates and so on — are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays; please see our terms for more details.

Any questions about your delivery? Contact the Sales Team on 01643 703358.

Thank you for your enquiry to return your order. 

Please note, we may not be able to provide a refund for the original carriage costs paid and there may be further charges for restocking and collection to apply before your refund is processed. 

Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

If goods have been used, installed or are returned in less than 100% as new condition & we agree to take them back, further costs may apply. Please see our terms and conditions or contact us for more information on your specific order. 

Need help choosing?

Talk to a
specialist

Sizing, regulations, installation. Our team has been answering these questions for over 25 years.

Why Tanks-Direct

22 years. 100,000+ tanks. Specialists, not generalists.

Nationwide delivery

GB and Northern Ireland covered. HIAB and crane offload available. Highlands and Islands quoted on request.

WRAS & BS EN compliant

Every potable tank is independently certified. Documentation supplied with each delivery.

Best-price guarantee

4.6/5 on Feefo from 1272 verified reviews. We price-match any genuine like-for-like quote.

Specialist advice

Trade-grade phone and email support, Mon-Fri 8am-5pm. Site visits for orders over £2,500.