Clearwater BioAir CW2 Sewage Treatment Plant - 6 Person
Available as Gravity or Pumped outlet options, the new Clearwater CW2 BioAir sewage treatment plant employs aerated technology, delivering a high level of water discharge quality.
With adaptable installation choices to accommodate diverse domestic locations and a discreet visual profile, the Clearwater BioAir stands as a financially sensible option for your household wastewater treatment needs.
Product Benefits:
- Affordable
- Suitable for shallow dig Installations
- Flexible installation & lightweight robust design
- Low impact visual footprint
- Supplied with isolator switch and failure light (High Level Alarm optional on IPS unit)
- 1-year warranty* (terms apply)
Typical Applications
- Single & Multiple Homes
- Barn Conversions
- Small Offices
- Farms
MAXIMUM INLET INVERT USING:
Gravity Units: Max Invert: 1400mm Pumped Units: Max Invert: 1000mm
*Please click on the following link to register your warranty.
https://www.kingspan.com/gb/en-gb/products/wastewater-management/guarantee
Commissioning
*Please note that additional commissioning costs may apply for certain Scottish Postcodes. These charges reflect the additional logistics required for servicing these areas. To confirm if your location incurs additional fees, please contact our customer service team for further information.
Commissioning prices apply at the time of purchasing the tank. Additional commissioning charges will apply if purchased separately from the tank.
Delivery
All our Clearwater tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.
If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off to the nearest hardstanding area only, at an additional cost). Please contact us if this is required for delivery.
| Diameter | Ø 1540 mm |
|---|---|
| Empty Weight | 170 kg |
| Material | HDPE / Polyethylene |
| Tank Use | Below Ground |
To ensure your system operates to maximum efficiency, we recommend tried and tested Commissioning by our own British Water and Safe Building trained engineers.
Our unrivalled knowledge means that we are best placed to carry out bespoke assessments to get your system up and running. The commissioning will also provide you with a unique checklist against your system, ensuring your complete peace of mind and reassurance that your system's mechanical and electrical components are in good working order.
The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.
- Check Plant is level, 5 mm tolerance
- Confirm the ground around the plant is level, flat and that the lid securely fastens
- Confirm the panel has been mounted correctly
- Make the required connections to the panel using correct glands
- Make all electrical connections within the tank
- Ensure all safety guards are fitted
- Set all greasomatics within the plant (if applicable)
- Check belt/chain tension and alignment
- Check pump float activates freely (pumped discharge only)
- Check operation of sludge return pump (nitrification plants only)
- Check direction of disc pack
- Check levels within unit
- Test and set any Alarms supplied with the unit
On completion, they will provide a site specific commissioning certificate
Find out more about what's included in the commissioning of your Clearwater sewage treatment plant and arrange Commissioning, read Kingspan's dedicated guide to Commissioning today.
*terms and conditions apply
*Please note that additional commissioning costs may apply for certain Scottish Postcodes. These charges reflect the additional logistics required for servicing these areas. To confirm if your location incurs additional fees, please contact our customer service team for further information.
Commissioning prices apply at the time of purchasing the tank. Additional commissioning charges will apply if purchased separately from the tank.
Important — please read
Please ensure the product you are ordering is the correct size and suitable for the purpose. Special order, bespoke and non-stock tanks are not returnable. If you order a tank and find it is too big, too small, or unsuitable for your requirements, it can be expensive to return. Our cancellation & returns policy explains this in more detail — see Terms & Conditions.
Delivery charges
Our shipping costs cover most of the UK. However, parts of England, the Scottish Highlands and Islands (including areas north of the Glasgow / Edinburgh border), Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs.
- AB
- BT
- CA
- CT
- DD
- DG
- EH
- FK
- G
- GY
- IM
- IV
- JE
- KA
- KW
- KY
- LD
- LL
- ML
- PA
- PH
- PO 30–41 Isle of Wight
- SA
- SY
- TD
- TN
- TR
- ZE
- Southern Ireland
Looking to avoid shipping charges?
All our tanks are available for collection ex works. Our suppliers are based all over the UK — please call if you wish to collect.
Overseas orders
International orders are welcome. Payment is by IBAN / SWIFT / BIC, MoneyGram and letters of credit. We regret that credit cards are not accepted for international orders.
A purchase order is required; we will then create a pro-forma invoice, and tanks are ordered on clearance of funds.
If you require additional export documentation — for example a Certificate of Origin, or commercial invoices certified by the Chamber of Commerce — you must notify us before completion of your order, as we will have to invoice cost and admin charges to the order.
Please call if you have any questions: +44 (0)1643 703358
Offloading
Unless a HIAB delivery has been booked at additional cost, it is the customer’s responsibility to offload with suitable equipment on the day of delivery. A failed delivery may result in additional charges.
We recommend that installers, plant hire and installation materials — excavators, aggregates and so on — are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays; please see our terms for more details.
Any questions about your delivery? Contact the Sales Team on 01643 703358.
Looking to return an item?
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.
Please click here to request a return of one of our products.
- Clearwater BioAir Datasheet
- Clearwater BioAir 2 Pumped (6PE) Sales Drawing
- Clearwater BioAir 2 & 3 Installation Manual
- Clearwater BioAir 2 Gravity (6PE) Sales Drawing
- DS1415P-02 Bioair 2-3 Extension Neck Details
- Kingspan Domestic Enhanced Pre Comms Checklist
- Smart Commissioning & Activation Brochure
Talk to a
specialist
Sizing, regulations, installation. Our team has been answering these questions for over 25 years.
Why Tanks-Direct
22 years. 100,000+ tanks. Specialists, not generalists.
Nationwide delivery
GB and Northern Ireland covered. HIAB and crane offload available. Highlands and Islands quoted on request.
WRAS & BS EN compliant
Every potable tank is independently certified. Documentation supplied with each delivery.
Best-price guarantee
4.6/5 on Feefo from 1272 verified reviews. We price-match any genuine like-for-like quote.
Specialist advice