SKU · CWP4

Clearwater 1250L Single Sewage Pumping Station

Customer Off Loading
Fast Delivery
GRP
Round
Sewage
Below Ground
DimensionsØ 900 mm
Your Price · Ex VAT
£1,033.00
£1,239.60 inc VAT

Estimate delivery costs

PayPal Pay in 3 Learn Klarna Pay in 30 days Learn

Clearwater 1250L Single Sewage Pumping Station - CWP4

Clearwater pumping systems are designed for homes that are built below the level of the mains sewage system, to pump effluent, sewage or rainwater, depending on the pump, distance and height required.

Pump Stations are used in connection with sewage treatment systems, septic tanks and rainwater harvesting systems (please check suitability before ordering)..

Appropriate where 24 hour storage requirements need to be maintained, Clearwater pumping stations are manufactured from low-maintenance GRP.

The Clearwater CWP4 model is Ideal for homes or small scale applications of up to 8 people and typical applications would include home extensions, outbuildings, pool houses and garden rooms.

Product Benefits

  • Manufactured from durable GRP.
  • Reliable performing stainless steel submersible pumps.
  • Supplied with control panel.
  • Choose from either 110 mm or 160 mm inlet connections.
  • Designed with easy access features for maintenance.
  • Macerator pump
  • Lockable covers for optimum security.
  • Optional quick connection outlet couplings.
  • Low Cost Commissioning

Twin Pump option available. Please contact our Sales Team on 01643 703358 for more information.

Clearwater 1250L Single Pump Station Specifications

Chamber Size (mm) Capacity (L) Tanks Material Control Panel Alarm Pump Type
900 x 2160 1250 GRP Included Optional Single/Twin

Delivery

All our Clearwater tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.

If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle).

Please contact us if this is required for delivery.

Product specifications for Clearwater 1250L Single Sewage Pumping Station
DiameterØ 900 mm
MaterialGRP / Fibreglass
ColourBrown
Tank UseBelow Ground

To size your pump stations, the key factors to take into consideration are below

  • Application: domestic, residential or commercial.
  • Material application: sewage, effluent or surface water.
  • Inlet depth (below ground level).
  • Pumping distance and lift.
  • Electrical supply.

 

If you require assistance with sizing your Pump station, please give our sales team a ring on 01643 703358.

 

 

Low Cost Commissioning

Benefits:

  • Reassurance that your system's mechanical and electrical components are in good working order

  • A warranty period that only starts when your water system is commissioned, not when it leaves the factory (terms and conditions apply)

  • Trouble-free operation of your system from the start

Find out more about what's included in the Commissioning of your Clearwater pump station and arrange Commissioning, read Kingspan's dedicated guide to Commissioning today.

 

The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.

  • Unit is installed flat and level with safe working area around the perimeter
  • All incoming and outgoing pipework has been connected
  • The control panel has been mounted
  • Permanent electrical supply has been fitted to the panel (extension leads or generator supplies will not be acceptable)
  • The following will then be carried out by an Authorised Service Engineer:
  • Check the system is installed to manufacturer's instruction
  • Fit floats in tank and set the levels
  • Pull float and pump cables through the ducts using drawstring provided
  • Connect pump and float cables to the control panel using appropriate glands (the panel must be within 2 m of the chamber or select “enhanced commissioning”)
  • Check float cable operation and terminate (stop, start, standby, alarm)
  • Check pump rotation
  • Run the pumps via the float switches to ensure correct operation and discharge
  • Test high level alarm and beacon (if applicable)
  • Leave on Auto for future use

Please note, Kingspan Commissioning covers UK mainland and certain postcode areas only. Please speak to our Team for expert advice on Commissioning.

Service and maintenance

Your pump station should be serviced bi-annually to prevent blockages or obstructions in the inlet or outlet pipes from occurring. Any service and maintenance works need to be carried out by a properly trained professional, with appropriate experience, especially with mechanical and electrical parts. For more information on service and maintenance plans, please give our team a call on 01643 703358. 

 

Estimated Lead time 5-7 working days

Important — please read

Please ensure the product you are ordering is the correct size and suitable for the purpose. Special order, bespoke and non-stock tanks are not returnable. If you order a tank and find it is too big, too small, or unsuitable for your requirements, it can be expensive to return. Our cancellation & returns policy explains this in more detail — see Terms & Conditions.

Delivery charges

Our shipping costs cover most of the UK. However, parts of England, the Scottish Highlands and Islands (including areas north of the Glasgow / Edinburgh border), Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs.

  • AB
  • BT
  • CA
  • CT
  • DD
  • DG
  • EH
  • FK
  • G
  • GY
  • IM
  • IV
  • JE
  • KA
  • KW
  • KY
  • LD
  • LL
  • ML
  • PA
  • PH
  • PO 30–41 Isle of Wight
  • SA
  • SY
  • TD
  • TN
  • TR
  • ZE
  • Southern Ireland

Looking to avoid shipping charges?

All our tanks are available for collection ex works. Our suppliers are based all over the UK — please call if you wish to collect.

Overseas orders

International orders are welcome. Payment is by IBAN / SWIFT / BIC, MoneyGram and letters of credit. We regret that credit cards are not accepted for international orders.

A purchase order is required; we will then create a pro-forma invoice, and tanks are ordered on clearance of funds.

If you require additional export documentation — for example a Certificate of Origin, or commercial invoices certified by the Chamber of Commerce — you must notify us before completion of your order, as we will have to invoice cost and admin charges to the order.

Please call if you have any questions: +44 (0)1643 703358

Offloading

Unless a HIAB delivery has been booked at additional cost, it is the customer’s responsibility to offload with suitable equipment on the day of delivery. A failed delivery may result in additional charges.

We recommend that installers, plant hire and installation materials — excavators, aggregates and so on — are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays; please see our terms for more details.

Any questions about your delivery? Contact the Sales Team on 01643 703358.

Looking to return an item?

If you wish to return goods, please complete the form on this page to provide further information.

Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods. 

Please click here to request a return of one of our products.

Need help choosing?

Talk to a
specialist

Sizing, regulations, installation. Our team has been answering these questions for over 25 years.

Phone 01643 703358Mon-Fri 8am-6pm WhatsApp Message usTap to open WhatsApp Email sales@tanks-direct.co.ukReply within 2 hours

Why Tanks-Direct

22 years. 100,000+ tanks. Specialists, not generalists.

Nationwide delivery

GB and Northern Ireland covered. HIAB and crane offload available. Highlands and Islands quoted on request.

WRAS & BS EN compliant

Every potable tank is independently certified. Documentation supplied with each delivery.

Best-price guarantee

4.6/5 on Feefo from 1272 verified reviews. We price-match any genuine like-for-like quote.

Specialist advice

Trade-grade phone and email support, Mon-Fri 8am-5pm. Site visits for orders over £2,500.