2000 Litre GRP Water Tank - FlyVar Compact Twin Booster Set
The space saving solution and almost silent running. The Tanks Direct Home Booster is designed to supply potable water to a single or multiple dwelling where mains pressure is insufficient. The Tanks Direct Home Booster comes complete with a variable speed drive(s) and submersible or surface mounted pump(s). The break-tank is insulated to keep the noise level to a minimum. Controls can be mounted on the top of the tank, allowing for easy maintenance. The Tanks Direct Home Booster is available in two standard sizes 500L and 1000L with single and twin pump options.
Standard Features
- GRP insulated water storage tank (WRAS Approved)
- 500L or 1000L (other sizes on request)
- Variable speed stainless steel submersible pump(s)
- Low water level pump protection (as standard)
- Common alarm volt free contactors
- Digital system display
- Max head Up to 6.5Bar
- Max Flow Up to 120L/Min
Applications
- Holiday Homes / Static Caravans
- Off the grid / Rural Properties
- High Rise Apartments / Flats
- Light Industrial use
- Washdown Stations (CAT5)
- Feed to Bib Taps (CAT5)
Supplied with
- 1 No 22mm screened lid vent
- 1 No 28mm Equilbrium float valve
- 1 No 18mm baseboard
- 1 No 42mm screened overflow
- 1 No 22mm screened warning pipe (tanks of 1000 litre and above only)
Please note this tank and pump set are not CAT5, if this is required, please contact us for more information
| Capacity (L) | 2000 |
| Pump Configuration | Twin |
| Inlet Size (mm) | 28 |
| Length (mm) | 2202 |
| WiIXO-DTh (mm) | 1202 |
| Height (mm) | 1606 |
| Model Number | Mid Curve Flow | Mid Curve Pressure | kW Rating | Running Current (amp) | Supply Voltage | Inlet | Outlet | Overflow Size | Dry Weight |
| FV40/10T | 80 l/min | 4.5 Bar | 2 x 0.75 | 2 x 3.8 | 1ph 230v 50hz | 3/4" | 1 1/4" | 40mm | 94kg |
| FV40/15T | 80 l/min | 6.5 Bar | 2 x 1.1 | 2 x 5.2 | 1ph 230v 50hz | 3/4" | 1 1/4" | 40mm | 96kg |
| FV80/15T | 120 l/min | 4.5 Bar | 2 x 1.1 | 2 x 5.4 | 1ph 230v 50hz | 3/4" | 1 1/4" | 40mm | 98kg |
| FV80/20T | 120 l/min | 5.8 Bar | 2 x 1.5 | 2 x 6.1 | 1ph 230v 50hz | 3/4" | 1 1/4" | 40mm | 100kg |
If access is an issue, please contact us, as we can offer a solution of a 2 piece GRP tank, which allows you to separate the 2 sections and carry them through a doorway or tight corridor for assembly in situ.
Each pump comes complete with an independent inverter, fixed to the vessel with Bluetooth connectivity to pair the inverts for duty assist functionality. No need for interconnecting wiring, making it easy for installation and testing. This versatile booster set can also pair with multiple FlyVar compacts, allowing for even more flow when space for situating the system is at even more of a premium.
Delivery
All our Compact booster sets are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.
If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.
Images are for illustration purposes only, the GRP tank would be Grey and not Blue as advertised
| Capacity | 2000 litres |
|---|---|
| Dimensions (W×L×H) | 1202 × 2202 × 1606 mm |
| Empty Weight | 10 kg |
Standard commissioning process
- Mount panel into the kiosk or suitable housing location supplied / identified by others.
- Drop draw cords down the 110mm cable duct already installed by others.
- Lower the pumps down the guide rails onto the pedestals and ensure correct position.
- Pull through the float and pump cables, if a cable extension is needed, this is extended within the chamber via a junction box and pulled through with a multicore cable.
- Take a electricity supply from a type C32 rotary isolator at the location of the panel.
- Connect the power to the control panel along with the 2 pump cables and the 4 control float cables.
- Set floats are the required heights to correspond with the inlet level.
- Fill the pump station if not already full.
- Power up the control panel and turn each pump into manual using the dials to amp test each pump and set the Lmax overload setting.
- Set the dials to auto and continue to fill to test standard operation
- Remove air locks if necessary
- Check duty assist and high level alarm function
- Leave the system in full working order
Important — please read
Please ensure the product you are ordering is the correct size and suitable for the purpose. Special order, bespoke and non-stock tanks are not returnable. If you order a tank and find it is too big, too small, or unsuitable for your requirements, it can be expensive to return. Our cancellation & returns policy explains this in more detail — see Terms & Conditions.
Delivery charges
Our shipping costs cover most of the UK. However, parts of England, the Scottish Highlands and Islands (including areas north of the Glasgow / Edinburgh border), Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs.
- AB
- BT
- CA
- CT
- DD
- DG
- EH
- FK
- G
- GY
- IM
- IV
- JE
- KA
- KW
- KY
- LD
- LL
- ML
- PA
- PH
- PO 30–41 Isle of Wight
- SA
- SY
- TD
- TN
- TR
- ZE
- Southern Ireland
Looking to avoid shipping charges?
All our tanks are available for collection ex works. Our suppliers are based all over the UK — please call if you wish to collect.
Overseas orders
International orders are welcome. Payment is by IBAN / SWIFT / BIC, MoneyGram and letters of credit. We regret that credit cards are not accepted for international orders.
A purchase order is required; we will then create a pro-forma invoice, and tanks are ordered on clearance of funds.
If you require additional export documentation — for example a Certificate of Origin, or commercial invoices certified by the Chamber of Commerce — you must notify us before completion of your order, as we will have to invoice cost and admin charges to the order.
Please call if you have any questions: +44 (0)1643 703358
Offloading
Unless a HIAB delivery has been booked at additional cost, it is the customer’s responsibility to offload with suitable equipment on the day of delivery. A failed delivery may result in additional charges.
We recommend that installers, plant hire and installation materials — excavators, aggregates and so on — are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays; please see our terms for more details.
Any questions about your delivery? Contact the Sales Team on 01643 703358.
Looking to return an item?
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.
Please click here to request a return of one of our products.
Talk to a
specialist
Sizing, regulations, installation. Our team has been answering these questions for over 25 years.
Why Tanks-Direct
22 years. 100,000+ tanks. Specialists, not generalists.
Nationwide delivery
GB and Northern Ireland covered. HIAB and crane offload available. Highlands and Islands quoted on request.
WRAS & BS EN compliant
Every potable tank is independently certified. Documentation supplied with each delivery.
Best-price guarantee
4.6/5 on Feefo from 1272 verified reviews. We price-match any genuine like-for-like quote.
Specialist advice
Trade-grade phone and email support, Mon-Fri 8am-5pm. Site visits for orders over £2,500.