Klargester Sewage Pumping Station from 1,500 - 2,200 litres - PU10 Range
Product Ref: PU1020SS
Key Factors to size your Pump Stations
To size your pump stations they key factors to take into consideration are below
- Application: domestic, residential or commercial.
- Material application: sewage, effluent or surface water.
- Inlet depth (below ground level).
- Pumping distance and lift.
- Electrical supply.
If you require assistance with sizing your Pump station, please give our sales team a ring on 01643 703358.
Video
Product Description
Klargester Sewage Pumping Station - PU10 Vertical Pump Station Range
Single or Twin Pump Options from 1,500 - 2,200 litres
Klargester vertical pumping stations are ideal for developments and premises where drainage by gravity is not an option.
Manufactured from MDPE, Klargester vertical pumping stations are designed as a single piece chamber engineered with the highest quality parts and fittings.
Available in a range of sizes, suitable for commercial applications from small roof run offs, to large SUDS schemes, Klargester vertical pumping stations deliver up to 70 litres/second and have 24-hour storage capacity for foul waste to comply with Building Regulations. .
All of our pump stations can be fitted, or retrofitted, with Kingspan's SmartServ Pro remote asset monitoring software to provide you with total visibility over the wastewater system across your estate
Product Benefits
- Internal lifting chains and guide rails (as specified).
- High-level alarm.
- Wide range of single or twin pump options including macerators/vortex.
- Range of emergency overflow tanks, if required.
- Inlet connection sizes to suit site.
- Wide range of invert depths and positions to suit applications.
- GRP chambers with internal pipework in plastic, galvanised or cast iron.
- Optional single door kiosk with warning beacons and optional telemetry systems.
- Service and maintenance plans available to prolong the life of the pump systems.
- Grundfos pumps for submerged installation.
Vertical Tanks Size (mm) | Capacity (L) | Case Depth | Tank Material | Control Panel | High Level Alarm | Pump Type Options |
1000 Diameter | 1500 | 2.0m | GRP | Included | Standard | Single/Twin |
1000 Diameter | 2200 | 2.5m | GRP | Included | Standard | Single/Twin |
Product Details
- Product Code: KLA
- Customer Offloading: Customer Offloading
- Delivery: Free Delivery
- Material: MDPE
- Tank Use: Below Ground, Sewage
- Twin or Single: Single, Twin
Do you require Commissioning?
Low Cost Commissioning
Benefits:
- Reassurance that your system's mechanical and electrical components are in good working order
- A warranty period that only starts when your water system is commissioned, not when it leaves the factory (terms and conditions apply)
- Trouble-free operation of your system from the start
To find out more about what's included in the Commissioning of your Kingspan Klargester pump station, or to arrange Commissioning, please click here for more information
Smart Commissioning – Standard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. Smartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge. (T&Cs apply).
Standard Commissioning
The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.
- Unit is installed flat and level with safe working area around the perimeter
- All incoming and outgoing pipework has been connected
- Permanent electrical supply has been fitted to the panel (extension leads or generator supplies will not be acceptable)
- The following will then be carried out by an Authorised Service Engineer:
- Check the system is installed to manufacturer's instruction
- Fit floats in tank and set the levels
- Pull float and pump cables through the ducts using drawstring provided
- Connect pump and float cables to the control panel using appropriate glands (the panel must be within 2 m of the chamber or select “enhanced commissioning”)
- Check float cable operation and terminate (stop, start, standby, alarm)
- Check pump rotation
- Run the pumps via the float switches to ensure correct operation and discharge
- Test high level alarm and beacon (if applicable)
- Leave on Auto for future use
Please note, Kingspan Commissioning covers UK mainland and certain postcode areas only. Please speak to our Team for expert advice on Commissioning.
Service and maintenance
Your pump station should be serviced bi-annually to prevent blockages or obstructions in the inlet or outlet pipes from occurring. Any service and maintenance works need to be carried out by a properly trained professional, with appropriate experience, especially with mechanical and electrical parts. For more information on service and maintenance plans, please give our team a call on 01643 703358.
Delivery
Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland
Our lead times should only be used as a guide and are subject to change.
Offloading
Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.
We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.
HIAB
HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.
If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.
Returns Information
Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.
Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **
All Items must be returned unused, refunds cannot be issued for used or previously installed items.
Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.
View Related Categories
People who bought this also bought...
from £5,138.00 ex VAT
(£6,165.60 inc VAT)
from £5,559.00 ex VAT
(£6,670.80 inc VAT)