Klargester Full Retention Separator - NSFP006 - 335M² drainage area
Product Ref: NSFP006
Estimated Lead time: 3-5 Working days
How to Size a Full Retention Separator?
To specify a nominal size full retention separator, the following information is required:
- The calculated flow rate for the drainage area served. our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the influent is not pumped.
- The required discharge standard. This will decide which class is required.
- The drain invert inlet depth
- Pipework type, size and orientation
Product Description
Klargester NSFP006 Full Retention Separator for 335m2 drainage area
The Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.
Full retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.
Kingspan Klaregsters range of full retention separators were the first UK manufacturer to have the required 3 -30 l/sec certified to EN 858-1 in the UK. The NSF number denotes the flow at which the separator operates.
Full Retention Separator Features
- Designed for easy installation, saving time and money
- Certified to EN858 - 1 and PPG3 for complete peace of mind
- Oil alarm probe tube available (required by EN858-1 and PPG3)
- Fitted inlet/ outlet connections
- Vent points within necks
- Maintenance from ground level
- PE and GRP model construction - high strength and durability
- CE - Marked
Applications
Klargesters full retention separators are used in high risk spillage areas such as:
- Fuel Distribution depots
- Vehicle workshops
- Scrap Yards
NSFP006 Specifications
- Model Reference: NSFP006
- Material: Polyethylene Chamber Construction
- Flow (l/s): 6
- Drainage Area (m2) PPG-3 (0.018): 335
- Storage Capacity (L) Silt: 600
- Storage Capacity (L) Oil: 60
- Length (mm): 1700
- Diameter (mm): 1350
- Manhole Cover Dimensions (mm): 600
- Base Inlet Invert (mm): 1410
- Base to Outlet invert (mm): 1335
- Min Inlet Invert (mm): 550
- Standard Pipework Diameter (mm): 160
Available with Smart Commissioning
Standard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind.
Smartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*
*Kingspan monitoring is for alert only.
Service/maintenance packages are available at separate cost on request.
Product Details
- Product Code: KLA
- Customer Offloading: Customer Offloading
- Delivery: Free Delivery
- Diameter: 1350mm
- HIAB Available: HIAB Available
- Material: Polyethylene
- Tank Use: Below Ground
Commissioning, Servicing & Maintenance
Benefits of having your Kingspan Klargester product commissioned:
- Reassurance that your system's mechanical and electrical components are in good working order
- A warranty period that only starts when your water system is commissioned, not when it leaves the factory (terms and conditions apply)
- Trouble-free operation of your system from the start
Find out more about what's included in the Commissioning of your Clearwater pump station and arrange Commissioning, read Kingspan's dedicated guide to Commissioning today.
The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.
- Unit is installed flat and level with safe working area around the perimeter
- All incoming and outgoing pipework has been connected
- The control panel has been mounted
- Permanent electrical supply has been fitted to the panel (extension leads or generator supplies will not be acceptable)
- The following will then be carried out by an Authorised Service Engineer:
- Check the system is installed to manufacturer's instruction
- Fit floats in tank and set the levels
- Pull float and pump cables through the ducts using drawstring provided
- Connect pump and float cables to the control panel using appropriate glands (the panel must be within 2 m of the chamber or select “enhanced commissioning”)
- Check float cable operation and terminate (stop, start, standby, alarm)
- Check pump rotation
- Run the pumps via the float switches to ensure correct operation and discharge
- Test high level alarm and beacon (if applicable)
- Leave on Auto for future use
Please note, Kingspan Commissioning covers UK mainland and certain postcode areas only. Please speak to our Team for expert advice on Commissioning.
How often should my separator be serviced?
Kingspan’s service and maintenance plans have been developed using our knowledge of a range of separators and in accordance with the Environmental Agency Pollution Prevention Guidelines and EN858-2.
Avoid flooding and fines with cost-effective separator service plans from Kingspan Service. By regularly servicing your separators you can reduce the pollution risk on your site.To find out more, click here
Delivery
Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland
Our lead times should only be used as a guide and are subject to change.
Offloading
Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.
We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.
HIAB
HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.
If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.
Returns Information
Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.
Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **
All Items must be returned unused, refunds cannot be issued for used or previously installed items.
Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.
View Related Categories
People who bought this also bought...
from £5,138.00 ex VAT
(£6,165.60 inc VAT)
from £1,601.00 ex VAT
(£1,921.20 inc VAT)