Sewage Pumping station, Twin Pumps, 1700 litre

 

Product Ref: MINIT50VP6H1700

MDPE Sewage
  • Volume: 1700ltr
  • Weight: 80.000kg
  • Dimensions: H:2000mm
  • Diameter: 1000mm
  • Estimated Lead time:2 - 3 working days

    Home Delivery

    UK mainland delivery from £65.00 ex VAT

    check delivery cost

    Choose option:

    updown
    You may also need:
    Double Door Kiosk
    Double Door Kiosk
    £925.00 ex VAT
    (£1,110.00 inc VAT)
    Kiosk Single Door
    Kiosk Single Door
    from £462.00 ex VAT
    (£554.40 inc VAT)

    Tank Specifications

     Model  MINI 1700 Twin
     Capacity  1700 Litres
     Diameter  1000 mm
     Height  2000 mm
     Access Cover - Size  600 x 600 mm 
     Access Cover - Rating  Pedestrian

    Video

    Product Description

    Sewage Pumping Station Twin Rigged - Dual Rigged -  Package Sewage Pumping Station


    A packaged pump station is used when gravity drainage on site cannot be achieved. The waste from the site flows into an underground storage chamber, where it is then pumped to the main sewer. Packaged pump stations can be used for both foul water (sewage) and surface water applications. Our packaged pump station systems are designed to have a 24-hour storage capacity and are manufactured to BSEN752-6 standards. The Dual Rigged Pump Station is suitable for a domestic sewage pumping station for use in areas where gravity flow is not available. It can be used for various drainage applications, with the system also used for the transfer of sewage or waste water, all specially designed for easy installation.

    The Dual Rigged is a compact sewage pump station suitable for small to large houses and also commercial applications, and is particularly suitable when water or sewage is collected lower than the main sewer or a septic tank system. All you need is supplied to you within the package, so you will just need to supply the pipework to and from the station, plus any fittings. A high water alarm is supplied as standard. The Pumping Station comes with a submersible pump with 50 mm solid handling for peace of mind. Our range of pumping stations is of a superior design and quality, to meet with BSEN75.6 requirements.

     

    Pump:

    • Cast iron/stainless steel construction
    • 50 mm (2") solids handling capacity
    • Coolant filled motor
    • Mechanical seal
    • 10 M cable
    • Max 10 M lift
    • Max flow 5 L/sec
    • Float switch as standard

    Controls

    • Twin control panel, c/w auto change over and high level alarm
    • 4 x 10 M float controls
    • 1 x float bracket

    Tank:

    • Polyethylene tank.
    • Dim: 1.0M x 2.0M D
    • Capacity 1700L
    • 1 x 110 mm / 160 mm inlet seal to allow inlet to be drilled on site.
    • 40 mm cable duct.
    • 2" internal pipe work
    • 2" non-return valve
    • 2" quick release coupling
    • 2" cable duct
    • Special audible/visual high level alarm control box available

     

    Delivery

    All our Pumping Stations are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.

    If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.

    Product Details

    • Product Code: DPT
    • Colour: Black
    • Diameter: 1000mm
    • Material: MDPE
    • Tank Use: Sewage

    Pump Specifications

    Model Ref  6VX 10VX MC
    Impeller Type Vortex Vortex Vortex
    Power Supply 230v 1ph 50hz
    Rated Power 0.3 kW 0.75 kW 1.2 kW
    Rated Current 1.9 A 4.0 A 9.2 A
    Max Head 6 Metres 10 Metres 16 Metres
    Max Flow Rate (Litres per sec) 5.5 l/s 7.9 l/s 1.8 l/s
    Cable Length 10 m 10 m 10 m
    Free Passage 50 mm 50 mm Macerator

    Pump Curves

    mini-pump-curves

    Commissioning

    Pump Station Commissioning

     

    • Full system inspection
    • Levels inspection
    • Man way check for obstruction
    • Mount control panel (if not in place)
    • Check correct load to panel
    • Check correct cable size
    • Check correct power supply
    • Set the overloads
    • Lower pumps via guide rail onto stools using an A-frame if required
    • Pull pump cables through ducting
    • Pull float cables through ducting
    • Set floats to correct operating position
    • Wire cables into control panel
    • Fill system with water
    • Full test of pump station
    • Sign-off and certification
    • Warranty and documentation provided

    Delivery

    Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

    Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

    Our lead times should only be used as a guide and are subject to change.

    Offloading

    Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

    We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

    HIAB

    HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.

    If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.

    Returns Information

    Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

    Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **

    All Items must be returned unused, refunds cannot be issued for used or previously installed items.

    Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

    If you wish to return goods, please complete the form on this page to provide further information.

    Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

    Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

    Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

    View Tanks Direct's return policy now.

    People who bought this also bought...