Clearwater 1600L Single Sewage Pumping Station
Product Ref: CWP5
Key Factors to size your Pump Stations
To size your pump stations, the key factors to take into consideration are below
- Application: domestic, residential or commercial.
- Material application: sewage, effluent or surface water.
- Inlet depth (below ground level).
- Pumping distance and lift.
- Electrical supply.
If you require assistance with sizing your Pump station, please give our sales team a ring on 01643 703358.
Product Description
Clearwater 1600L Single Sewage Pumping Station - CWP5
The Clearwater CWP5 model is designed for small scale applications, built below the level of the mains sewage system to pump effluent, sewage or rainwater, depending on the pump, distance and height required.
Ideal for homes or small scale applications of up to 10 people, typical applications would include home extensions, outbuildings, pool houses and garden rooms.
Appropriate where 24 hour storage requirements need to be maintained, Clearwater pump stations are used in connection with sewage treatment systems, septic tanks and rainwater harvesting systems (please check suitability before ordering).
Product Benefits
- Manufactured from durable GRP.
- Reliable performing stainless steel submersible pumps.
- Supplied with control panel.
- Choose from either 110 mm or 160 mm inlet connections.
- Designed with easy access features for maintenance.
- Lockable covers for optimum security.
- Optional quick connection outlet couplings.
- Low Cost Commissioning
Twin Pump option available. Please contact our Sales Team on 01643 703358 for more information.
Chamber Size (mm) | Capacity (L) | Tank Material | Control Panel | Alarm | Pump Type |
900 x 2670 | 1600 | GRP | Included | Optional | Single/Twin |
Delivery
All our Clearwater tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.
If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.
Product Details
- Product Code: CLW
- Colour: Brown
- Customer Offloading: Customer Offloading
- Delivery: Fast Delivery
- Diameter: 900mm
- Material: GRP
- Shape: Round
- Tank Use: Below Ground, Sewage
- Twin or Single: Single
Do you require Commissioning?
Low Cost Commissioning
Benefits:
- Reassurance that your system's mechanical and electrical components are in good working order
- A warranty period that only starts when your water system is commissioned, not when it leaves the factory (terms and conditions apply)
- Trouble-free operation of your system from the start
Find out more about what's included in the Commissioning of your Clearwater pump station and arrange Commissioning, read Kingspan's dedicated guide to Commissioning today.
The checks below will be carried out by a Kingspan Service Engineer and will only be checked if the unit has been installed in line with the provided installation guidelines.
- Unit is installed flat and level with safe working area around the perimeter
- All incoming and outgoing pipework has been connected
- The control panel has been mounted
- Permanent electrical supply has been fitted to the panel (extension leads or generator supplies will not be acceptable)
- The following will then be carried out by an Authorised Service Engineer:
- Check the system is installed to manufacturer's instruction
- Fit floats in tank and set the levels
- Pull float and pump cables through the ducts using drawstring provided
- Connect pump and float cables to the control panel using appropriate glands (the panel must be within 2 m of the chamber or select “enhanced commissioning”)
- Check float cable operation and terminate (stop, start, standby, alarm)
- Check pump rotation
- Run the pumps via the float switches to ensure correct operation and discharge
- Test high level alarm and beacon (if applicable)
- Leave on Auto for future use
Please note, Kingspan Commissioning covers UK mainland and certain postcode areas only. Please speak to our Team for expert advice on Commissioning.
Service and maintenance
Your pump station should be serviced bi-annually to prevent blockages or obstructions in the inlet or outlet pipes from occurring. Any service and maintenance works need to be carried out by a properly trained professional, with appropriate experience, especially with mechanical and electrical parts. For more information on service and maintenance plans, please give our team a call on 01643 703358.
Delivery
Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland
Our lead times should only be used as a guide and are subject to change.
Offloading
Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.
We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.
HIAB
HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.
If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.
Returns Information
Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.
Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **
All Items must be returned unused, refunds cannot be issued for used or previously installed items.
Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.