450 Litre Sewage Pumping Station
Product Ref: MICROS50VP6H450
Estimated Lead time: 1- 2 working days
Tank Specifications
Model | MICRO 450 |
Capacity | 450 Litres |
Diameter | 610 mm |
Height | 1500 mm |
Access Cover - Size | 450 mm |
Access Cover - Rating | Pedestrian |
Video
Product Description
FS Micro 450 Litre Sewage Pumping Station
A packaged pump station is used when gravity drainage on site cannot be achieved. The waste from the site flows into an underground storage chamber, where it is then pumped to the main sewer. Packaged pump stations can be used for both foul water (sewage) and surface water applications. Our packaged pump station systems are designed to have a 24 hour storage capacity and are manufactured to BSEN752-6 standards.
The FS Micro 450 Litre Pumping Station is suitable for a domestic sewage pumping station for use in areas where gravity flow is not available. It can be used for various drainage applications, the mini system can also used for the transfer of sewage or waste water, designed for easy installation. FS Micro 450 Litre is a small sewage pump station that is suitable for extensions, garden rooms and small applications Particularly suitable when water or sewage is collected lower than the main sewer or a septic tank system. All you need is supplied so you just need to supply the pipework to and from the station, plus any fittings. There is also available a high water alarm if required. The FS Micro 450 Litre Pumping Station comes with a submersible pump with 50mm solid handling for peace of mind
Pump:
- Cast iron/stainless steel construction.
- 50 mm (2") solids handling capacity
- Coolant filled motor.
- Mechanical seal.
- 10 Meter cable.
- Max 6 Meter lift.
- Max flow 5 L/sec
- Float switch as standard.
Tank:
- Polyethylene tank.
- 450 L capacity.
- Screw down lid (Pedestrian rated)
- 1 x 110 mm / 160 mm inlet seal to allow inlet to be drilled on site.
- 40 mm cable duct.
- 2" internal pipe work
- 2" non-return valve
- 2" quick release coupling
- 2" cable duct
- Special audible/visual high level alarm control box available.
Delivery
All our Sewage Pumping Stations are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.
If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.
Product Details
- Product Code: DPT
- Colour: Black
- Delivery: Fast Delivery
- Diameter: 610mm
- Material: Polyethylene
- Shape: Round
- Stock tank: Stock tank
- Tank Use: Below Ground, Sewage
- Twin or Single: Single
Pump Specifications
Commissioning
Pump Station Commissioning
Full system inspection
Levels inspection
Manway check for obstruction
Mount control panel (if not in place)
Check correct load to panel
Check correct cable size
Check correct power supply
Set the overloads
Lower pumps via guiderail onto stools using an A-frame if required
Pull pump cables through ducting
Pull float cables through ducting
Set floats to correct operating position
Wire cables into control panel
Fill system with water
Full test of pump station
Sign-off and certification
Warranty and documentation provided
Delivery
Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland
Our lead times should only be used as a guide and are subject to change.
Offloading
Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.
We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.
HIAB
HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.
If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.
Returns Information
Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.
Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **
All Items must be returned unused, refunds cannot be issued for used or previously installed items.
Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.