3' Keraflo KP Type, Inline and Variable Delayed Action Float Valve, 80mm Description


Keraflo KP Type 3' - 80mm Inline and Variable Delayed Action Float Valve Please note delivery on KP type valves is around 6-8 weeks



Aylesbury KP type float valve kits comprises an in-line control valve together with an Aylesbury KB type float valve acting as a pilot. The pilot valve offers fully variable delayed action opening and closing water level settings, making this ideal for mains or pumped systems.





Other standout features of our Aylesbury 'KP' type float valve kits include the following:
- High Kv Value


The standard 'KP' Control Valve offers excellent flow rate performance.


Raised Valve Chamber


Can be small as it only has to accommodate a 3/4' KB valve and discharge assembly.


Facilitates Air Gaps


The Aylesbury 'KB' Valve is supplied with a 2m long adjustable chain as standard allowing the closing level to be set below any combination of  Weir Slot, Overflow and/or Warning Device.


Quiet Operation


Aylesbury valves are quieter than conventional valves due to the elimination of Water Hammer, Valve Bounce, 'Hiss' and Dribble.


Accessibility


An externally mounted Control Valve can be easily - inspected, adjusted and if required serviced. Re-chlorination of the tank is not necessary provided the tank lid is not removed.


Optional Extra


Upstream Pressure Sustaining Regulator - the Control Valve regulates itself to leave the desired minimum upstream pressure (Adjustable 1 - 6 Bar). This can also be used to provide a constant flow rate.





Benefits


No Water Hammer


Full Flow During Fill


Maximises Tank Capacity


Maintenance Free


No backing plate required


Suitable for all types of Air Gap applications


No Valve Bounce


No Dribble


Delayed Action


Tank Wall Stress negligible


Ideal for Fire Sprinkler Systems


Flexibility and ease of Installation





Conventional Float Valves above 3' are heavy and cumbersome often necessitating a two person installation. When the 'KP' Control Valve is mounted outside the tank at floor level, no heavy lifting is required.





The Control Valve can be mounted in one of four positions:


Vertically in the pipe work (preferred option)


Outside the tank at floor level


Outside the tank above the tank water level


Inside the tank above the tank water level


Multiple Discharges





To reduce the risk of stagnation, two or more discharges can be connected to the outlet of the control valve. Since the Filling Pipe is only subjected to low pressure, thin wall PVC pipe can be used. The 'KP' Valve can also be configured to service twin/partitioned tanks.





Shallow Tanks - 'KP' Valves can operate in tanks as shallow as 1 metre in depth.





Deep Tanks - The standard Aylesbury 'KB' Pilot valve enables an opening level 2m below the inlet level. A longer chain can be supplied if required.



Product Details

  • Product Code: PW
  • Outlet Size: 3" BSP Male
  • Stock tank: Non Returnable Product

Delivery

Our shipping costs cover most of the UK - however, parts of England, Scottish Highlands and Islands including areas north of the Glasgow / Edinburgh border, Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.

Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs. AB, BT, CA, CT, DD, DG, EH, FK, G, GY, IM, IV, JE, KA, KW, KY, LD, LL, ML, PA, PH, PO 30-41 (Isle of Wight), SA, SY, TD, TN, TR, ZE Southern Ireland

Our lead times should only be used as a guide and are subject to change.

Offloading

Unless a hi-ab delivery has been booked at additional cost, it is the customer's responsibility to offload with suitable equipment on the day of delivery and a failed delivery may result in additional charges.

We recommend installers and/or plant hire & materials to install such as excavators, aggregates etc are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays, please see our terms for more details.

HIAB

HIAB delivery will be required if you need the tank offloaded from the delivery vehicle. The driver will unload the tank from the vehicle to ground level, however this service is not to place the tank in situ, this will need to be arranged separately.

If you have any questions regarding your delivery, please contact the Sales Team on 01643 703358.

Returns Information

Please note - Certain items may not be returnable, for example those made to order or for sanitary reasons. Please check the product page for more information.

Customers may return items within 14 calendar days (as per our Terms & Conditions) - refer to section 7. **

All Items must be returned unused, refunds cannot be issued for used or previously installed items.

Please be aware that returning a tank can be complicated and expensive, so please check that you are ordering the correct item (we suggest checking the dimensions very carefully).

If you wish to return goods, please complete the form on this page to provide further information.

Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.

Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.

Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.

View Tanks Direct's return policy now.

People who bought this also bought...