Sewage Pumping Station 1800Dia Twin Rigged 7300 Litre
Twin Rigged GRP - Package Sewage Pumping Station. A packaged pump station is used when gravity drainage on site cannot be achieved. The waste from the site flows into an underground storage chamber, where it is then pumped to the main sewer. Packaged pump stations can be used for both foul water (sewage) and surface water applications. Our packaged pump station systems are designed to have a 24-hour storage capacity and are manufactured to BSEN752-6 standards. The Twin Rigged 7300 Litre Pump Station is suitable for a domestic sewage pumping station for use in areas where gravity flow is not available. It can be used for various drainage applications, with the system also used for the transfer of sewage or waste water, all specially designed for easy installation. The Twin Rigged 7300 Litre Pump station is a compact sewage pump station suitable for small to large houses and also commercial applications. The Twin Rigged Pump Station is available in 5000/6000/7300 Litre capacities and is particularly suitable when water or sewage is collected lower than the main sewer.
All you need is supplied to you within the package, so you will just need to supply the pipework to and from the station, plus any fittings. A high water alarm is supplied as standard. The Pumping Station comes with a submersible pump with 50 mm solid handling for peace of mind. Our range of pumping stations is of a superior design and quality, to meet with BSEN75.6 requirements.
Pump:
- Cast iron / stainless steel construction
- 50 mm (2") solids handling capacity - 50 mm Macerator – 65 mm solids handling – 80 mm solids handling.
- Coolant filled motor
- Mechanical seal
- 10 M cable
- Max 6 M lift
- Max flow 5 L/sec
- Float switch as standard
- Controls
- Twin control panel, c/w auto change over and high level alarm
- 4 x 10 M float controls
- 1 x float bracket
Tank:
- GRP tank.
- Dim: 1.8dia x 2.0deep – 1.8dia x 2.5deep – 1.8dia x 3.0deep
- Capacity: 5000,6000,7200 Litres
- 1 x 110 mm / 160 mm inlet seal to allow inlet to be drilled on site.
- 100 mm cable duct.
- 2" – 3” internal pipe work
- 2" – 3” non-return valve
- 2" – 3” quick release coupling
- 110 mm cable duct
Delivery
All our Sewage Pumping Stations are for delivery by customer offload. This entails the customer to acquire the right manpower and/or machinery to help unload the tank/s from the delivery vehicle.
If you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.
| Diameter | Ø 1800 mm |
|---|---|
| Height | 3000 mm |
| Material | HDPE / Polyethylene |
Pump Station Commissioning
- Full system inspection
- Levels inspection
- Man way check for obstruction
- Mount control panel (if not in place)
- Check correct load to panel
- Check correct cable size
- Check correct power supply
- Set the overloads
- Lower pumps via guide rail onto stools using an A-frame if required
- Pull pump cables through ducting
- Pull float cables through ducting
- Set floats to correct operating position
- Wire cables into control panel
- Fill system with water
- Full test of pump station
- Sign-off and certification
- Warranty and documentation provided
Important — please read
Please ensure the product you are ordering is the correct size and suitable for the purpose. Special order, bespoke and non-stock tanks are not returnable. If you order a tank and find it is too big, too small, or unsuitable for your requirements, it can be expensive to return. Our cancellation & returns policy explains this in more detail — see Terms & Conditions.
Delivery charges
Our shipping costs cover most of the UK. However, parts of England, the Scottish Highlands and Islands (including areas north of the Glasgow / Edinburgh border), Isle of Wight, Channel Islands, Isle of Man, Anglesey, Western Isles, Shetland Islands, Orkney Islands, Isles of Scilly, Northern Ireland and the Republic of Ireland may cost more.
Please call before ordering if the delivery postcode is listed below. There may be additional shipping costs.
- AB
- BT
- CA
- CT
- DD
- DG
- EH
- FK
- G
- GY
- IM
- IV
- JE
- KA
- KW
- KY
- LD
- LL
- ML
- PA
- PH
- PO 30–41 Isle of Wight
- SA
- SY
- TD
- TN
- TR
- ZE
- Southern Ireland
Looking to avoid shipping charges?
All our tanks are available for collection ex works. Our suppliers are based all over the UK — please call if you wish to collect.
Overseas orders
International orders are welcome. Payment is by IBAN / SWIFT / BIC, MoneyGram and letters of credit. We regret that credit cards are not accepted for international orders.
A purchase order is required; we will then create a pro-forma invoice, and tanks are ordered on clearance of funds.
If you require additional export documentation — for example a Certificate of Origin, or commercial invoices certified by the Chamber of Commerce — you must notify us before completion of your order, as we will have to invoice cost and admin charges to the order.
Please call if you have any questions: +44 (0)1643 703358
Offloading
Unless a HIAB delivery has been booked at additional cost, it is the customer’s responsibility to offload with suitable equipment on the day of delivery. A failed delivery may result in additional charges.
We recommend that installers, plant hire and installation materials — excavators, aggregates and so on — are not booked until you are in receipt of the goods. Tanks Direct cannot be held responsible for costs incurred due to unforeseen delays; please see our terms for more details.
Any questions about your delivery? Contact the Sales Team on 01643 703358.
Looking to return an item?
If you wish to return goods, please complete the form on this page to provide further information.
Once your request is approved, a valid Returns Authorisation Number (RAN) will be issued to initiate the returns process along with information on how & where to return your order along with any costs involved.
Please DO NOT return any goods without this authorisation. Goods cannot be accepted without this.
Returns are not accepted at our Minehead Office, please wait until we contact you before returning any goods.
Please click here to request a return of one of our products.
Talk to a
specialist
Sizing, regulations, installation. Our team has been answering these questions for over 25 years.
Why Tanks-Direct
22 years. 100,000+ tanks. Specialists, not generalists.
Nationwide delivery
GB and Northern Ireland covered. HIAB and crane offload available. Highlands and Islands quoted on request.
WRAS & BS EN compliant
Every potable tank is independently certified. Documentation supplied with each delivery.
Best-price guarantee
4.6/5 on Feefo from 1272 verified reviews. We price-match any genuine like-for-like quote.
Specialist advice
Trade-grade phone and email support, Mon-Fri 8am-5pm. Site visits for orders over £2,500.