Category 364 Products

DirectPumps & Tanks

Pumps and tanks, direct.

Our core range of pumps and water tanks for domestic and commercial supply. Storage and pumping solutions across every capacity.
364 Products
From £14 Starting price
4.8/5 Feefo · 1,277 reviews

364 products

  • 3300 Litre Underground Water Tank
    Direct Pumps & Tanks · BT3300P

    3300 Litre Underground Water Tank

    £1,256.00
    EX VAT · £1,507.20 INC
    View product
  • 1' Single Pump Booster Set, 50 l/min @ 3.5 Bar
    Direct Pumps & Tanks · 1-MX306RS/8TD

    Single Pump Variable Speed Booster Set, 50l/min @ 4.5 Bar

    £1,275.00
    EX VAT · £1,530.00 INC
    View product
  • FarmWash Washdown Kit
    Direct Pumps & Tanks · FW1

    FarmWash Washdown Kit

    £1,277.00
    EX VAT · £1,532.40 INC
    View product
  • 1900 Litre Foul Water - Mini Single Pump Station
    Direct Pumps & Tanks · MINI1900SGR65VX

    Sewage Pumping Station, Single Pump, 1900 Litre Tank

    £1,850.00
    EX VAT · £2,220.00 INC
    View product
  • 4400 Litre Underground Water Tank
    Direct Pumps & Tanks · BT4400P.

    4400 Litre Underground Water Tank

    £1,318.00
    EX VAT · £1,581.60 INC
    View product
  • Archimede ITTP 5.5W-RS booster pump inverter
    Direct Pumps & Tanks · ITTP5.5W-RS3PH

    Archimede ITTP 5.5W-RS booster pump inverter

    £1,323.00
    EX VAT · £1,587.60 INC
    View product
  • 1.25' Single Pump Booster Set, 75 l/min @ 5.0 Bar
    Direct Pumps & Tanks · 1-MX506RS/8TD

    Single Pump Variable Speed Booster Set, 75l/min @ 5.0 Bar

    £1,363.00
    EX VAT · £1,635.60 INC
    View product
  • 1.5' Single Pump Booster Set, 160 l/min @ 3.5 Bar
    Direct Pumps & Tanks · 1-MX1004RS/8TD

    Single Pump Variable Speed Booster Set, 160l/min @ 3.5 Bar

    £1,376.00
    EX VAT · £1,651.20 INC
    View product
  • 50l/min @ 4.5bar CAT5 67L Single Variable Speed Pump Booster Set & Tank
    Direct Pumps & Tanks · MICRO/306/CAT5

    50l/min @ 4.5bar CAT5 67L Single Variable Speed Pump Booster Set & Tank

    £1,441.00
    EX VAT · £1,729.20 INC
    View product
  • 1' Single Pump Booster Set, 50 l/min @ 4.5 Bar
    Direct Pumps & Tanks · 1-MX308RS/8TD

    Single Pump Variable Speed Booster Set, 50l/min @ 5.25 Bar

    £1,444.00
    EX VAT · £1,732.80 INC
    View product
  • Grundfos 54L/MIN @ 4.5 BAR
    Direct Pumps & Tanks · 1RS5-5/8/GF

    Vari-Rs Featuring Grundfos Single booster Pump With TD Variable Speed Controller 54L/MIN @ 4.5 BAR

    £1,449.00
    EX VAT · £1,738.80 INC
    View product
  • 5300 Litre Underground Water Tank
    Direct Pumps & Tanks · BT5300P

    5300 Litre Underground Water Tank

    £1,453.00
    EX VAT · £1,743.60 INC
    View product
  • Grundfos  36L/MIN @ 4.5 BAR
    Direct Pumps & Tanks · 1RS3-5/8/GF

    Vari-Rs Featuring Grundfos Single booster Pump With TD Variable Speed Controller 36L/MIN @ 4.5 BAR

    £1,454.00
    EX VAT · £1,744.80 INC
    View product
  • 1000 Litre Garden Angel
    Direct Pumps & Tanks · GA1000

    1000 Litre Garden Angel

    £1,468.00
    EX VAT · £1,761.60 INC
    View product
  • Grundfos 54L/MIN @ 4.5 BAR
    Direct Pumps & Tanks · 1RS3-7/8/GF

    Vari-Rs Featuring Grundfos Single booster Pump With TD Variable Speed Controller, 36L/MIN @ 6.5 BAR

    £1,469.00
    EX VAT · £1,762.80 INC
    View product
  • 2400 Litre SiltMaxx SM2000
    Direct Pumps & Tanks · SM2000

    2400 Litre SiltMaxx SM2000

    £1,502.00
    EX VAT · £1,802.40 INC
    View product
Need help choosing?

Talk to a
specialist

Sizing, regulations, installation. Our team has been answering these questions for over 25 years.

Phone 01643 703358Mon-Fri 8am-6pm WhatsApp Message usTap to open WhatsApp Email sales@tanks-direct.co.ukPrompt, courteous replies
Need help?

Direct Pumps & Tanks FAQs

Do I need a pump with my water storage tank, or can it feed by gravity?

This depends on where the tank sits relative to the point of use. If the tank is elevated above the outlets, gravity may provide enough pressure for basic uses like garden irrigation. For mains-pressure applications such as indoor plumbing, toilet flushing or pressurised garden systems, you'll need a pump to deliver adequate flow and pressure.

How do I choose the right pump size for my tank and application?

Pump selection comes down to two figures: flow rate (litres per minute) and head (the vertical lift plus pipe friction losses the pump must overcome). A rainwater harvesting system feeding a single toilet needs far less capacity than a whole-house or commercial setup. If you're unsure, tell us the number of outlets and the pipe run distance and we can help match a pump to the job.

Can I use a submersible pump in any tank?

Submersible pumps need enough clearance and depth to sit fully submerged without drawing in sediment from the base, so tank shape and outlet position matter. Most of our rainwater and sewage-rated tanks are designed with submersible pump chambers or sumps built in. Always check the pump's cable length and float switch clearance against the tank's internal dimensions before ordering.

What's the difference between a surface pump and a submersible pump?

A surface pump sits outside the tank, drawing water up through a suction pipe, and is easier to access for servicing but limited in suction lift (typically around 7-8 metres). A submersible pump sits inside the tank itself, pushing water rather than pulling it, which makes it more efficient for deeper tanks or longer vertical lifts. For most below-ground water tanks, submersible is the more reliable choice.

Do sewage and effluent pumps need to be different from clean water pumps?

Yes — sewage and effluent pumps use a cutting or vortex impeller designed to pass solids without clogging, whereas clean water pumps will jam or fail quickly if used on wastewater. Make sure any pump fitted to a septic tank, holding tank or sewage treatment plant is specifically rated for foul water use. Using the wrong type is a common cause of premature pump failure and blocked systems.

What maintenance does a tank pump system need once it's installed?

Check float switches and non-return valves periodically to make sure they move freely, and inspect any inline filters or strainers for debris, especially on rainwater harvesting systems after heavy leaf-fall. Submersible pumps should be lifted out and checked annually for wear on seals and impellers. For sewage pumps, an annual service is sensible to catch early signs of clogging or motor strain before they cause a system failure.