{"product_id":"secoh-jdk-s-60-single-series-blower","title":"SECOH JDK-S-60 Single Series Blower","description":"\u003ch2\u003e\u003cspan style=\"font-size:11pt\"\u003e\u003cspan style=\"font-size:18.0pt\"\u003eSECOH JDK-S-60 Single Series Blower Complete with Cable\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eSECOH JDK-S-60\u003c\/strong\u003e is a linear-diaphragm (electromagnetic oscillation) air blower, designed as a modern, energy-efficient replacement for older EL\/LP\/HP-60 models. \u003c\/p\u003e\n\n\u003cp\u003eIt is engineered for continuous duty aeration service in wastewater treatment, sewage systems, and other applications where dependable, oil-free air supply is needed.\u003c\/p\u003e\n\n\u003cp\u003eThe JDK models are a direct replacement of the Secoh EL series of blower. They feature up to 30% less energy consumption, as well as being more compact than the EL series.\u003c\/p\u003e\n\n\u003cp\u003eThis model is to be used in the Biosafe\/ CLP6 unit, located on the inside of the unit.\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cspan style=\"font-size:14px\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\u003cspan style=\"font-size:14px\"\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eEnergy-efficient design\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eConsumes less power (up to ~30% less than comparable older EL Series)\u003c\/p\u003e\n\n \u003cp\u003ethanks to reduced Internal friction and optimised electromagnetic drive\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eCompact, Lightweight construction\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eSmaller footprint and lower weight (6.5 kg) make it easier to install or retrofit\u003c\/p\u003e\n\n \u003cp\u003ein constrained plant enclosures\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eOil-Free Airflow\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eNo oil lubrication is needed, so the delivered air is clean and free of oil\u003c\/p\u003e\n\n \u003cp\u003evapour or contaminants - critical for water\/ biozones\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eLow noise \u0026amp; low vibration\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eThe unit features a built-in muffler chamber and vibration isolation\u003c\/p\u003e\n\n \u003cp\u003ebetween motor and pump parts to reduce acoustic disturbance\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003ePulsation-Free flow\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eSpecially shaped pump chambers and muffling result in a smoother,\u003c\/p\u003e\n\n \u003cp\u003esteadier airflow, better suited for fine diffuser systems\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eRobust, weather - resistant housing\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eThe blower is rated as rainproof \/ weatherproof (but should be\u003c\/p\u003e\n\n \u003cp\u003esheltered from direct sun, rain, snow)\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eModular Serviceability\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e\n\n \u003cp\u003eStandard spare kits (diaphragms, valve boxes, filters) are available\u003c\/p\u003e\n\n \u003cp\u003eand easy to replace, minimising downtime\u003c\/p\u003e\n\n \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eAPPLICATIONS\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eWater treatment\u003c\/li\u003e\n\n\t\u003cli\u003ePonds \u0026amp; Domestic applications\u003c\/li\u003e\n\n\t\u003cli\u003eMedical and health technology\u003c\/li\u003e\n\n\t\u003cli\u003eAeration of fuel cell stacks\u003c\/li\u003e\n\n\t\u003cli\u003eAqua-air-lights and design pillars\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003e\nTechnical:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eMax Flow: 60 Litres per Minute\u003c\/li\u003e\n\n\t\u003cli\u003eOptimal Operating Pressure: 0.20 Bar\u003c\/li\u003e\n\n\t\u003cli\u003eConnector Size: 19mm\u003c\/li\u003e\n\n\t\u003cli\u003eSound level (at 1.5m): 38dB\u003c\/li\u003e\n\n\t\u003cli\u003eVoltage: 230 VAC\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003ePlease note: The Secoh S-series air blowers come with a standard EU plug, these can be removed without effecting warranty\u003c\/p\u003e\n\n\u003ch3\u003e\u003cem\u003eTANK SERVICING\u003c\/em\u003e\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eWhy does my system need serviced?\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eIt’s important that your sewage treatment plant or septic tank system is emptied and maintained regularly to continue operating optimally.\u003c\/li\u003e\n\n\t\u003cli\u003ePoorly performing systems can cause serious health hazards as well as local pollution risks.\u003c\/li\u003e\n\n\t\u003cli\u003eRecent Building Regulations (Part H 2010 – BS EN 12566) state that regular emptying and maintenance of small sewage treatment plants must be undertaken by the homeowner at least once per year, or as per the manufacturer’s guidelines.\u003c\/li\u003e\n\n\t\u003cli\u003eAs a homeowner, you must also ensure that your system remains in good order and replace it when necessary.\u003c\/li\u003e\n\n\t\u003cli\u003eWe do recommend that you keep a detailed log of when your system is inspected, maintained, emptied or serviced as you may need these details in future.\u003c\/li\u003e\n\n\t\u003cli\u003eOur treatment plant service includes a full check to ensure everything is in perfect working order.\u003c\/li\u003e\n\n\t\u003cli\u003eOur team can be reached on \u003ca href=\"mailto:helpingyou@kingspan.com\"\u003ehelpingyou@kingspan.com\u003c\/a\u003e or 033 240 6868\u003c\/li\u003e\n\n\t\u003cli\u003e\u003cstrong\u003eCurrent lead time is 7–10 days for service visit\u003c\/strong\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003ePostcode exclusions apply to AB, BT, DD, EH, FK, G, GY, HS, IM, IV, JE, KA, KW, KY, ML, PA20+ \u0026amp; PH, PO30+, ZE\u003c\/strong\u003e\u003c\/p\u003e","brand":"Kingspan Parts","offers":[{"title":"Default Title","offer_id":56703671599429,"sku":"0015451","price":130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/7409_20063.jpg?v=1778768896","url":"https:\/\/tanks-direct.co.uk\/products\/secoh-jdk-s-60-single-series-blower","provider":"Tanks Direct","version":"1.0","type":"link"}