{"product_id":"klargester-full-retention-separator-nsfa030-1670ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA030 - 1670MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFA030 Full Retention Separator for 1670m² drainage area\u003c\/h2\u003e\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003cbr\u003eFull Retention Separator Features\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003c\/li\u003e\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\t\u003cli\u003ePE and GRP model construction - high strength and durability\u003c\/li\u003e\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:1250px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003eNSFA030 Technical Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eFlow (l\/s)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eStorage Capacity (L) Silt\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eStorage Capacity (L) Oil\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eLength (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eDiameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eManhole Cover Dimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eBase Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eBase to Outlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eMin Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eStandard Pipework Diameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eNSFA030\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eGRP Chamber Construction\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e30\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1670\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3000\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e300\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3915\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2010\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e600\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1810\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1760\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1000\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e315\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703783928133,"sku":"NSFA0301AGAK","price":4045.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3990_17658.jpg?v=1767800066","url":"https:\/\/tanks-direct.co.uk\/products\/klargester-full-retention-separator-nsfa030-1670ma2-drainage-area","provider":"Tanks Direct","version":"1.0","type":"link"}