{"product_id":"klargester-bypass-separator-nsbp003-1670m-drainage-area","title":"Klargester Bypass Separator - NSBP003 - 1670MÂ² Drainage Area","description":"\u003ch2\u003eKlargester NSBP003 Bypass Separator - 1670M² Drainage Area\u003c\/h2\u003e\n\n\u003cp\u003eThe Klargester Bypass Separator NSBP003 is an advanced solution engineered to efficiently manage surface water run-off while preventing pollutants from entering drainage systems. Engineered for efficiency and reliability, this separator is essential for protecting the environment from pollutants while ensuring compliance with local regulations. Its robust construction and innovative design make it suitable for a wide range of applications, from small residential projects to large commercial developments.\u003c\/p\u003e\n\n\u003cp\u003eBypass separators are used when it is considered an acceptable risk to not provide full treatment for very high flows, such as, where the risk of a large spillage and heavy rainfall occurring at the same time is small.\u003c\/p\u003e\n\n\u003cp\u003eTypical applications include surface car parks, roadways and lightly contaminated commercial areas.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Benefits\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eLight and easy to install.\u003c\/li\u003e\n\n\t\u003cli\u003eInclusive of silt storage volume.\u003c\/li\u003e\n\n\t\u003cli\u003eFitted inlet\/outlet connectors.\u003c\/li\u003e\n\n\t\u003cli\u003eVent points within necks.\u003c\/li\u003e\n\n\t\u003cli\u003eOil alarm system available (required by EN 858-1 and PPG3).\u003c\/li\u003e\n\n\t\u003cli\u003eExtension access shafts for deep inverts.\u003c\/li\u003e\n\n\t\u003cli\u003eMaintenance from ground level.\u003c\/li\u003e\n\n\t\u003cli\u003eGRP or polyethylene construction (subject to model).\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003ePerformance \u0026amp; Compliance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eFully compliant and tested to EN 858-1.\u003c\/li\u003e\n\n\t\u003cli\u003eBypass separators are tested by British Standards institute (BSI).\u003c\/li\u003e\n\n\t\u003cli\u003eCertified flow and process performance, assessing effluent qualities to the requirements of EN 858-1.\u003c\/li\u003e\n\n\t\u003cli\u003eThe unit is designed to treat the ‘first flush’ - 10% of peak flow. \u003c\/li\u003e\n\n\t\u003cli\u003eClass I separators are designed to achieve a concentration of less than 5 mg per litre.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eNSFP003 Specifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eModel Reference:\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eNSBP003\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e:\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003ePolyethylene Chamber Construction\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eFlow (l\/s):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e3\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eDrainage Area (m2) PPG-3 (0.018):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1670\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\n\u003cstrong\u003eStorage Capacity (L) Silt\u003c\/strong\u003e:\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e300\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eStorage Capacity (L) Oil:\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e45\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eLength (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1700\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eDiameter (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1350\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\n\u003cstrong\u003eManhole Cover Dimensions (m\u003c\/strong\u003e\u003cstrong\u003em):\u003c\/strong\u003e\n\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e600\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eBase Inlet Invert (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1420\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eBase Outlet Invert (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1320\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eMin Inlet Invert (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e500\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff; text-align:center\"\u003e\u003cstrong\u003eStandard Pipework Diameter (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e160 (Larger pipework options available on request)\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\n\u003cp\u003eStandard commissioning as scope of works, Inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eKingspan Klargester Bypass Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions (FAQs)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px\"\u003eHow often should the separator be maintained?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eMaintenance frequency depends on the amount of surface water run-off and the level of pollutants. Typically, a routine inspection every 6–12 months is recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px\"\u003eCan this separator handle heavy rainfall?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes, Klargester Bypass Separator NSPB003 is designed to efficiently manage high volumes of surface water, making it suitable for areas prone to heavy rainfall.\u003c\/p\u003e\n\n\u003cp\u003e\u003cspan style=\"font-size:14px\"\u003e\u003cstrong\u003eIs the Separator easy to install?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp\u003eInstallation is straightforward, and it can be managed by a qualified technician. Detailed installation guidelines are provided with the product.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px\"\u003eWhat happens if the separator becomes full?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe separator is designed to handle overflow, However, regular maintenance is essential to prevent blockages and ensure optimal performance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"font-size:14px\"\u003eIs the Separator environmentally friendly?\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eYes, the NSBP003 is designed to protect water quality by preventing pollutants from entering natural water bodies, making it an eco-friendly choice for stormwater management.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"160mm Pipework","offer_id":56926788419909,"sku":"NSBP0031CAK","price":1014.0,"currency_code":"GBP","in_stock":true},{"title":"315mm Pipework","offer_id":56926788452677,"sku":"NSBP0031GAK","price":1014.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/38731_25701.jpg?v=1778768864","url":"https:\/\/tanks-direct.co.uk\/products\/klargester-bypass-separator-nsbp003-1670m-drainage-area","provider":"Tanks Direct","version":"1.0","type":"link"}