{"product_id":"250-litre-type-ab-air-gap-grp-water-tank-two-piece-with-insulation-cat-5","title":"250 Litre Type AB Air Gap GRP Water Tank - Two Piece with Insulation, Cat 5","description":"\u003cp\u003e\u003cstrong\u003e250 Litre 2 Piece GRP Break Water Tank - Insulated (25mm) Full WRAS approval.\u003cbr\u003e\u003c\/strong\u003e\u003cstrong style=\"line-height: 19px;\"\u003eProduct Image is an example only showing a 2 piece tank with AB air gap.\u003c\/strong\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003eManufactured to meet BS7491 Parts 1 and 2, using the highest quality GRP materials, ensuring a long service life with minimal maintenance requirements. Grey colour as standard (other RAL or BS colours are available at additional cost). Only materials of the highest quality are used along with a highly efficient manufacturing processes. This combination ensures that these tanks are of the highest quality available.\u003cbr\u003e\n\nTank comes with float valve housing to suit drop arm equilibrium float valves up to 35mm. A float valve housing that is suitable for equilibrium drop arm float valves up to 54mm is available as an optional extra. Manufactured to meet BS7491 Parts 1 and 2, using the highest quality GRP materials, ensuring a long service life with minimal maintenance requirements. Delivery generally 2 weeks. (Made to order non-returnable)\u003cbr\u003e\n\nAll internal surfaces, including the lid, have an Isophthalic white gelcoat layer which provides a clinical smooth surface which will not support the growth of microbiological organisms. This gelcoat layer is reinforced by the main GRP laminate which provides the main structure of the tank body. The materials used are of the highest quality and applied with exacting production standards to assist in prevention of osmotic blistering. Further reinforcement is provided by square section steel tubing with fully welded corner joints. Steel reinforcement ensures that the softening and general deterioration encountered with timber supports is avoided, thus providing full structural reinforcement for the life of the tank.\u003cbr\u003e\nAfter the CFC free PU foam insulation and the steel reinforcement are fitted, the GRP outer skin is then applied. This ensures that both insulation and reinforcement are fully encapsulated and protected from external conditions. The whole tank is then coated with a tack free grey polyester gelcoat layer. This ensures that the tanks are suitable for all locations and weather conditions and can be located outdoors as standard. Where access is a limiting factor and our one piece GRP tanks are unsuitable a two piece tank could do the trick. These tanks are manufactured in two or more horizontally split sections which are then assembled once the restriction has passed. In a nutshell a one piece tank in two or more bolt together sections.\u003cbr\u003e\nAll of the components including sealant and fixings for the joint flange are supplied with the tank. The assembly of this range of products could not be easier and should not prove difficult for any competent mechanical services engineer. These two piece tanks allow utilization of the more cost effective one-piece type tank format, where a considerably more expensive sectional tank would traditionally have been supplied.\u003c\/p\u003e\n\n\u003cp style=\"line-height: 19px;\"\u003e\u003cstrong\u003eNominal capacity shown\u003cbr\u003e\u003c\/strong\u003eNominal capacity = full capacity to top of tank\u003cbr\u003e\n\nActual capacity = float level\u003c\/p\u003e\n\n\u003cp style=\"line-height: 19px;\"\u003e\u003cstrong\u003ePlease note: valves and fittings are supplied loose (items can be fitted to the tank for an additional fee).\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp style=\"line-height: 19px;\"\u003e\u003cstrong\u003eTank is supplied with 2 low level connection pads, on the opposite end to the inlet.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOptional steel water tank support Stand\u003c\/strong\u003e\u003cbr\u003e\n\n- Steel water tank support Stand suitable for raising the tank, allowing pump sets or other equipment to be positioned underneath.\u003cbr\u003e\n\n- Allows maximum use of the available footprint.\u003cbr\u003e\n\n- Increases the static head for applications where pressurised feed to equipment is advantageous.\u003cbr\u003e\n\n- Suitable for Two piece tanks.\u003cbr\u003e\n\n- Painted Grey Primer finish.\u003cbr\u003e\n\n- Manufactured in bolt up sections allowing easy access and assembly\u003cbr\u003e\n\n- Supplied with ply boarding to provide a flat solid surface for the tank base\u003cbr\u003e\n\n- 1100 x 600 x 1050mm (1000mm clearance to underside)\u003cbr\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003cbr\u003e\n\n\u003cstrong\u003eAnnual Disinfection Information and Options\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eDesigned for easy installation, saving time and money\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eAll work is carried out by CSCS qualified engineers\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eFull tank replacement works available\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eLegionella risk assessments including schematic drawings if required\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eBuilding flush and mains injection\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eCommissioning of booster sets\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eServicing of water softners and booster sets\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eReplacement of hollow roof struts.\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003cspan style=\"font-size: 13.91px;\"\u003eInsulating of existing cold water storage tanks\u003c\/span\u003e\n\u003c\/li\u003e\n\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"25mm Insulation (Standard)","offer_id":56926622712133,"sku":"PW250-2-AB","price":989.0,"currency_code":"GBP","in_stock":true},{"title":"50mm Insulation","offer_id":56926622744901,"sku":"PW250-2-AB.50mm.INS","price":1138.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/4412_7274.jpg?v=1769007363","url":"https:\/\/tanks-direct.co.uk\/products\/250-litre-type-ab-air-gap-grp-water-tank-two-piece-with-insulation-cat-5","provider":"Tanks Direct","version":"1.0","type":"link"}