{"title":"Glass Reinforced Plastic Tanks","description":"","products":[{"product_id":"1000-litre-grp-pump-enclosure-with-built-in-tank-cat-5-ab-air-gap","title":"1000 Litre GRP Pump Enclosure with built in Tank, CAT 5 AB air gap","description":"\u003cp\u003e\u003cstrong\u003eGRP Tank Combination Unit 1000 Litre, CAT 5 AB air gap\u003c\/strong\u003e\u003cbr\u003e\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water which is accessed via a lid mounted lockable manway. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600mm hinged and lockable door, which is fitted with louvered vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid the whole unit is mounted and fixed too a fully welded galvanised steel skid which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a \"plug and play' unit requiring minimal onsite installation.\u003cbr\u003e\n\u003cstrong\u003e\u003cem\u003eAll units are fitted with the following:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n1 No 50mm screened lid vent\u003cbr\u003e\n\n1 No single 1600 x 1600mm door to the end face of the pump compartment\u003cbr\u003e\n\n1 No lockable access manway fitted to the roof of the wet compartment.\u003cbr\u003e\n\n1 No EPDM mat to the floor of the pump compartment\u003cbr\u003e\n\nA fully encapsulated ply base.\u003cbr\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only which should be flat, level and continuous and be +\/- 2mm over the surface area.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid have an external height 200mm less than stated in the overall dimensions column of this document\u003cbr\u003e\n\u003cstrong\u003eAvailability 5-6 weeks\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003e**Cat 5 (AB and AG) supplied loose\u003c\/strong\u003e\u003cbr\u003e\nAG Airgap\u003cbr\u003e\n\nIP22-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AG-SL\u003cbr\u003e\n\n50mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nAB Airgap\u003cbr\u003e\n\nIP22-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003eCU1.1000AB data\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\n \u003ctd\u003e1620 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eActual Capacity Approx.\u003c\/td\u003e\n\n \u003ctd\u003e1000 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eOverall Dimensions\u003c\/td\u003e\n\n \u003ctd\u003e2200 x 2000 x 2250mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eWet Compartment\u003c\/td\u003e\n\n \u003ctd\u003e500 x 1800 x 1800mm \u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003ePump Compartment\u003c\/td\u003e\n\n \u003ctd\u003e1500 x 1800 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745261893,"sku":"CU1.1000AB","price":9495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c922-2-d95fbbaf.jpg?v=1768235784"},{"product_id":"1000-litre-grp-enclosure-with-built-in-tank-and-80l-min-twin-pump","title":"1000 Litre GRP Enclosure with built in tank and 80L\/min twin pump","description":"\u003ch2\u003e1000 Litre GRP Enclosure with built-in tank and 80L\/min twin pump\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework.\u003cbr\u003e\nThe dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation. If chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003cbr\u003e\n\u003cstrong\u003e\u003cem\u003eAll units are fitted with the following:\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 50 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1600 x 1600 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eTwin Pump - 80L\/min as standard, however other options are available\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e**Pictures are for illustration purposes only\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745294661,"sku":"CU1.1000TWP","price":12325.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c922-5-10a24515.jpg?v=1768235788"},{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-cat-5-ab-air-gap","title":"3000 Litre GRP Pump Enclosure with built in Tank, CAT 5 AB air gap","description":"\u003cp\u003e\u003cstrong\u003eGRP Tank Combination Unit 3000 Litre, CAT 5 AB air gap\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water which is accessed via a lid mounted lockable manway. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600mm hinged and lockable door, which is fitted with louvered vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid the whole unit is mounted and fixed too a fully welded galvanised steel skid which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a \"plug and play' unit requiring minimal onsite installation.\u003cbr\u003e\n\u003cstrong\u003e\u003cem\u003eAll units are fitted with the following:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n1 No 50mm screened lid vent\u003cbr\u003e\n\n1 No single 1600 x 1600mm door to the end face of the pump compartment\u003cbr\u003e\n\n1 No lockable access manway fitted to the roof of the wet compartment.\u003cbr\u003e\n\n1 No EPDM mat to the floor of the pump compartment\u003cbr\u003e\n\nA fully encapsulated ply base.\u003cbr\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only which should be flat, level and continuous and be +\/- 2mm over the surface area.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid have an external height 200mm less than stated in the overall dimensions column of this document\u003cbr\u003e\n\u003cstrong\u003eAvailability 5-6 weeks\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003e**Cat 5 (AB and AG) supplied loose\u003c\/strong\u003e\u003cbr\u003e\nAG Airgap\u003cbr\u003e\n\nIP22-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AG-SL\u003cbr\u003e\n\n50mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nAB Airgap\u003cbr\u003e\n\nIP22-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003eCU2.3000AB Data\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\n \u003ctd\u003e4200 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eActual Capacity Approx.\u003c\/td\u003e\n\n \u003ctd\u003e3000 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eOverall Dimensions\u003c\/td\u003e\n\n \u003ctd\u003e2700 x 2000 x 2250mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eWet Compartment\u003c\/td\u003e\n\n \u003ctd\u003e1300 x 1800 x 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003ePump Compartment\u003c\/td\u003e\n\n \u003ctd\u003e1200 x 1800 x 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745392965,"sku":"CU2.3000AB","price":9283.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2367_24848.jpg?v=1767875770"},{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"3000 Litre GRP Pump Enclosure with built in Tank,  AG air gap","description":"\u003ch2\u003e3000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e \u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e**Images are for illustration purposes only\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745458501,"sku":"CU2.3000AG","price":9072.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2368_24837.jpg?v=1767875771"},{"product_id":"4000-litre-grp-pump-enclosure-with-built-in-tank-cat-5-ab-air-gap","title":"4000 Litre GRP Pump Enclosure with built in Tank, CAT 5 AB air gap","description":"\u003cp\u003e\u003cstrong\u003eGRP Tank Combination Unit 4000 Litre, CAT 5 AB air gap\u003c\/strong\u003e\u003cbr\u003e\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water which is accessed via a lid mounted lockable manway. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600mm hinged and lockable door, which is fitted with louvered vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid the whole unit is mounted and fixed too a fully welded galvanised steel skid which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a \"plug and play' unit requiring minimal onsite installation.\u003cbr\u003e\n\u003cstrong\u003e\u003cem\u003eAll units are fitted with the following:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n1 No 50mm screened lid vent\u003cbr\u003e\n\n1 No single 1600 x 1600mm door to the end face of the pump compartment\u003cbr\u003e\n\n1 No lockable access manway fitted to the roof of the wet compartment.\u003cbr\u003e\n\n1 No EPDM mat to the floor of the pump compartment\u003cbr\u003e\n\nA fully encapsulated ply base.\u003cbr\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only which should be flat, level and continuous and be +\/- 2mm over the surface area.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid have an external height 200mm less than stated in the overall dimensions column of this document\u003cbr\u003e\n\u003cstrong\u003eAvailability 5-6 weeks\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003e**Cat 5 (AB and AG) supplied loose\u003c\/strong\u003e\u003cbr\u003e\nAG Airgap\u003cbr\u003e\n\nIP22-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AG-SL\u003cbr\u003e\n\n50mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nAB Airgap\u003cbr\u003e\n\nIP22-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003eCU3.4000AB Data\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\n \u003ctd\u003e5500 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eActual Capacity Approx.\u003c\/td\u003e\n\n \u003ctd\u003e4000 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eOverall Dimensions\u003c\/td\u003e\n\n \u003ctd\u003e3600 x 2000 x 2250mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eWet Compartment\u003c\/td\u003e\n\n \u003ctd\u003e1700 x 1800 x 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003ePump Compartment\u003c\/td\u003e\n\n \u003ctd\u003e1700 x 1800 x 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745491269,"sku":"CU3.4000AB","price":12010.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2373_24847.jpg?v=1767875771"},{"product_id":"5000-litre-grp-pump-enclosure-with-built-in-tank-cat-5-ab-air-gap","title":"5000 Litre GRP Pump Enclosure with built in Tank, CAT 5 AB air gap","description":"\u003cp\u003e\u003cstrong\u003eGRP Tank Combination Unit 5000 Litre, CAT 5 AB air gap\u003c\/strong\u003e\u003cbr\u003e\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water which is accessed via a lid mounted lockable manway. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600mm hinged and lockable door, which is fitted with louvered vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid the whole unit is mounted and fixed too a fully welded galvanised steel skid which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a \"plug and play' unit requiring minimal onsite installation.\u003cbr\u003e\n\u003cstrong\u003e\u003cem\u003eAll units are fitted with the following:\u003c\/em\u003e\u003c\/strong\u003e\u003cbr\u003e\n\n1 No 50mm screened lid vent\u003cbr\u003e\n\n1 No single 1600 x 1600mm door to the end face of the pump compartment\u003cbr\u003e\n\n1 No lockable access manway fitted to the roof of the wet compartment.\u003cbr\u003e\n\n1 No EPDM mat to the floor of the pump compartment\u003cbr\u003e\n\nA fully encapsulated ply base.\u003cbr\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only which should be flat, level and continuous and be +\/- 2mm over the surface area.\u003cbr\u003e\n\nUnits not fitted with a galvanised steel skid have an external height 200mm less than stated in the overall dimensions column of this document\u003cbr\u003e\n\u003cstrong\u003eAvailability 5-6 weeks\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003e**Cat 5 (AB and AG) supplied loose\u003c\/strong\u003e\u003cbr\u003e\nAG Airgap\u003cbr\u003e\n\nIP22-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AG-SL\u003cbr\u003e\n\n42mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AG-SL\u003cbr\u003e\n\n50mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nAB Airgap\u003cbr\u003e\n\nIP22-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n22mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n35mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP28-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n28mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n42mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP35-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n35mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n50mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP42-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n42mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n67mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003cbr\u003e\nIP50-AB-SL\u003cbr\u003e\n\n22mm screened lid vent\u003cbr\u003e\n\n50mm equilibrium float valve c\/w drop arm and float\u003cbr\u003e\n\n80mm screened overflow\u003cbr\u003e\n\n22mm screened warning pipe\u003c\/p\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003eCU3.5000AB Data\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eNominal Capacity\u003c\/td\u003e\n\n \u003ctd\u003e7100 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eActual Capacity Approx.\u003c\/td\u003e\n\n \u003ctd\u003e5000 Litres\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eOverall Dimensions\u003c\/td\u003e\n\n \u003ctd\u003e3600 x 2000 x 2250mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003eWet Compartment\u003c\/td\u003e\n\n \u003ctd\u003e2200 x 1800 x 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003ePump Compartment\u003c\/td\u003e\n\n \u003ctd\u003e1200 x 1800 x 1800mm\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745556805,"sku":"CU3.5000AB","price":12342.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2378_24846.jpg?v=1767875771"},{"product_id":"500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1000-500","title":"500 Litre GRP Pump Enclosure with built in Tank, AG air gap 1000-500","description":"\u003ch2\u003e500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 800 x 800 mm single hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift truck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 800 x 800 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e**Pictures are for illustration purposes only\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745655109,"sku":"CUCOMP.1000-500","price":2156.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45580_21251.jpg?v=1767875772"},{"product_id":"8000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-12000-8000","title":"8000 Litre GRP Pump Enclosure with built in Tank, AG air gap 12000-8000","description":"\u003ch2\u003e8000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745687877,"sku":"CUCOMP.12000-8000","price":13910.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45667_21442.jpg?v=1767875772"},{"product_id":"1000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1500-1000","title":"1000 Litre GRP Pump Enclosure with built in Tank, AG air gap 1500-1000","description":"\u003ch2\u003e1000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745786181,"sku":"CUCOMP.1500-1000","price":2581.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45621_21338.jpg?v=1767875771"},{"product_id":"500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1500-500","title":"500 Litre GRP Pump Enclosure with built in Tank, AG air gap 1500-500","description":"\u003ch2\u003e500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 22 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746539845,"sku":"CUCOMP.1500-500","price":2560.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45591_21331.jpg?v=1767875771"},{"product_id":"750-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1500-750","title":"750 Litre GRP Pump Enclosure with built in Tank, AG air gap 1500-750","description":"\u003ch2\u003e750 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746572613,"sku":"CUCOMP.1500-750","price":2570.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45593_21332.jpg?v=1767875771"},{"product_id":"1500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3001-1500","title":"1500 Litre GRP Pump Enclosure with built in Tank, AG air gap 3001-1500","description":"\u003ch2\u003e1500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746638149,"sku":"CUCOMP.3001-1500","price":4269.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45636_21377.jpg?v=1767875772"},{"product_id":"2143-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3636-2143","title":"2143 Litre GRP Pump Enclosure with built in Tank, AG air gap 3636-2143","description":"\u003ch2\u003e2143 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746703685,"sku":"CUCOMP.3636-2143","price":4626.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45638_21381.jpg?v=1767875772"},{"product_id":"3375-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-5625-3375","title":"3375 Litre GRP Pump Enclosure with built in Tank, AG air gap 5625-3375","description":"\u003ch2\u003e3375 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746736453,"sku":"CUCOMP.5625-3375","price":6760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45654_21402.jpg?v=1767875772"},{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-7500-3000","title":"3000 Litre GRP Pump Enclosure with built in Tank, AG air gap 7500-3000","description":"\u003ch2\u003e3000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746769221,"sku":"CUCOMP.7500-3000","price":7935.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45658_21406.jpg?v=1767875772"},{"product_id":"4500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-7500-4500","title":"4500 Litre GRP Pump Enclosure with built in Tank, AG air gap 7500-4500","description":"\u003ch2\u003e4500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746834757,"sku":"CUCOMP.7500-4500","price":7935.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45655_21404.jpg?v=1767875773"},{"product_id":"2250-litre-grp-sectional-water-tank-internally-flanged-base-ifb","title":"2250 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB)","description":"\u003ch2\u003e2250 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e2250 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x1.5.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1650 x 1450 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2450 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789072709,"sku":"PW.1.5x1x1.5.IFB","price":2153.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/4208_18860.jpg?v=1767875798"},{"product_id":"2250-litre-grp-sectional-water-tank-internally-flanged-base-ab-airgap-ifb","title":"2250 Litre GRP Sectional Water Tank, Internally Flanged Base, AB Airgap (IFB","description":"\u003ch2\u003e2250 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e2250 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x1.5.IFB-AB Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1650 x 1450 x 2050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2450 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789105477,"sku":"PW.1.5x1x1.5.IFB-AB","price":2302.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36355_18894.jpg?v=1767875797"},{"product_id":"3130-litre-grp-sectional-water-tank-internally-flanged-base-tif","title":"3130 Litre GRP Sectional Water Tank, Internally Flanged Base (TIF)","description":"\u003ch2\u003e3130 Litre Sectional Water Tank, Totally Internally Flanged (TIF)\u003c\/h2\u003e\n\u003cp\u003e3130 Litre GRP Sectional Water Tank, a sectional tank with an totally internally flanged and internally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eTIF tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eTIF tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eA Totally Internally Flanged Tank (TIF) is one of the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, internally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 38 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eFixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x1.5.TIF Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Nominal Capacity\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3130 Litres\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1750 x 1250 x 1900 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e50 mm to 3 sides, 600 mm to one face - Height required 2400 mm \u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789171013,"sku":"PW.1.5x1x1.5.TIF","price":4350.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/46147_22401.jpg?v=1767875797"},{"product_id":"1500-litre-grp-sectional-water-tank-internally-flanged-base-ifb","title":"1500 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB)","description":"\u003ch2\u003e1500 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e1500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x1.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eAirgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eExternal Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1650x1150x1250mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eAssembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650x2150x1750mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789203781,"sku":"PW.1.5x1x1.IFB","price":1795.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/4209_18781.jpg?v=1767875798"},{"product_id":"1500-litre-grp-sectional-water-tank-1-5x1x1-internally-flanged-base-ab-airgap","title":"1500 Litre GRP Sectional Water Tank, 1.5x1x1 Internally Flanged Base AB Airgap","description":"\u003ch2\u003e1500 Litre Sectional Water Tank, Internally Flanged Base (IFB) Airgap\u003c\/h2\u003e\n\u003cp\u003e1500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x1.IFB-AB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1650x1150x1550mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650x2150x2050mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789269317,"sku":"PW.1.5x1x1.IFB-AB","price":1890.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/35891_18832.jpg?v=1767875749"},{"product_id":"1500-litre-grp-sectional-water-tank-internally-flanged-base-ifb-divided","title":"1500 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided","description":"\u003ch2\u003e1500 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided\u003c\/h2\u003e\n\u003cp\u003e1500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e1x1x1 \u0026amp; 0.5x1x1m high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x1.IFB-AG.DIV (1+0.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 1x1x1 \u0026amp; 0.5x1x1m high compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e650x1150x1250mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650x2150x1750mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789302085,"sku":"PW.1.5x1x1.IFB-AG.DIV (1+0.5)","price":1958.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/35892_18833.jpg?v=1767875748"},{"product_id":"3000-litre-grp-sectional-water-tank-1-5x1x2-internally-flanged-base-ifb","title":"3000 Litre GRP Sectional Water Tank, 1.5x1x2 Internally Flanged Base (IFB)","description":"\u003ch2\u003e3000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e3000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x2.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1650 x 1450 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2450 x 2750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789367621,"sku":"PW.1.5x1x2.IFB","price":2348.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36626_18945.jpg?v=1767875748"},{"product_id":"3000-litre-grp-sectional-1-5x1x2-water-tank-internally-flanged-base-divided-ab-airgap","title":"3000 Litre GRP Sectional 1.5x1x2 Water Tank, Internally Flanged Base, Divided, AB Airgap","description":"\u003ch2\u003e3000 Litre Sectional Water Tank, Internally Flanged Base (IFB), Divided, AB Airgap\u003c\/h2\u003e\n\u003cp\u003e3000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e1x1x1 \u0026amp; 0.5x1x1m high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1.5x1x2.IFB.AB.DIV(1+0.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 1000 x 1000 x 2000 \u0026amp; 500 x 1000 x 2000 high compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1650 x 1150 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2150 x 3050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789400389,"sku":"PW.1.5x1x2.IFB.AB.DIV(1+0.5)","price":3023.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/42047_19639.jpg?v=1767875748"},{"product_id":"1500-litre-grp-sectional-water-tank-1x1x1-5-internally-flanged-base-ifb","title":"1500 Litre GRP Sectional Water Tank, 1x1x1.5 Internally Flanged Base (IFB)","description":"\u003ch2\u003e1500 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e1500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.5.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eAirgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eExternal Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150 x 1150 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eAssembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150 x 2150 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789465925,"sku":"PW.1x1x1.5.IFB","price":1682.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36314_18887.jpg?v=1767875749"},{"product_id":"1500-litre-grp-sectional-water-tank-internally-flanged-base-ab-airgap","title":"1500 Litre GRP Sectional Water Tank, Internally Flanged Base AB Airgap","description":"\u003ch2\u003e1500 Litre Sectional Water Tank, Internally Flanged Base (IFB) Airgap\u003c\/h2\u003e\n\u003cp\u003e1500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.5.IFB-AB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150 x 1150 x 2050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150 x 2150 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789531461,"sku":"PW.1x1x1.5.IFB-AB","price":1765.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36316_18889.jpg?v=1767875687"},{"product_id":"1500-litre-grp-sectional-water-tank-1x1x1-5-0-5-0-5-internally-flanged-base-ifb-divided","title":"1500 Litre GRP Sectional Water Tank, 1x1x1.5(0.5+0.5) Internally Flanged Base (IFB) Divided","description":"\u003ch2\u003e1500 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided\u003c\/h2\u003e\n\u003cp\u003e1500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e0.5x1x1.5 high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.5.IFB-AG.DIV (0.5+0.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Airgap\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Single or twin compartment (Divided)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No. 500 x 1000 x 1500 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e External Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150 x 1150 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Assembly area required\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150 x 2150 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789629765,"sku":"PW.1x1x1.5.IFB-AG.DIV (0.5+0.5)","price":1992.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/38099_19139.jpg?v=1767875687"},{"product_id":"2182-litre-grp-sectional-water-tank-totally-internally-flanged-tif","title":"2182 Litre GRP Sectional Water Tank, Totally Internally Flanged (TIF)","description":"\u003ch2\u003e2182 Litre Sectional Water Tank, Totally Internally Flanged (TIF)\u003c\/h2\u003e\n\u003cp\u003e2182 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and internally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eTIF tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eTIF tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eA Totally Internally Flanged Tank (TIF) is one of the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, Internally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 38 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eFixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.5.TIF Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eAirgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eNominal Capacity\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2182 Litres\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eExternal Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1250 x 1250 x 1900 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eAssembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e50 mm to 3 sides, 600 mm to one face - Height required 2400 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789662533,"sku":"PW.1x1x1.5.TIF","price":3376.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/46110_22326.jpg?v=1767875688"},{"product_id":"1000-litre-grp-sectional-water-tank-internally-flanged-base-ifb","title":"1000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB)","description":"\u003ch2\u003e1000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\n\u003cp\u003e1000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003e\n\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.IFB Dimensions\u003c\/p\u003e\n\n\t\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Air gap\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1150x1150x1250mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2150x2150x1750mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003cp\u003eFor more information regarding this service, please see - \u003cstrong\u003e\u003ca href=\"https:\/\/www.tanks-direct.co.uk\/grp-commissioning\"\u003eDoes your water tank need a clean?\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1 to 3 years\u003c\/li\u003e\n\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789728069,"sku":"PW.1x1x1.IFB","price":1406.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c1436-2-b72c6398.jpg?v=1768235496"},{"product_id":"1000-litre-grp-sectional-water-tank-internally-flanged-base-in-500mm-panels-ifb","title":"1000 Litre GRP Sectional Water Tank, Internally Flanged Base in 500mm Panels (IFB)","description":"\u003ch2\u003e1000 Litre Sectional Water Tank, Internally Flanged Base in 500mm Panels (IFB)\u003c\/h2\u003e\n\n\u003cp\u003e1000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. This variant is for tight access areas where it has been restricted to anything up to 550mm.\u003c\/p\u003e\n\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003e\n\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.IFB Dimensions\u003c\/p\u003e\n\n\t\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Air gap\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1150x1150x1250mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2150x2150x1750mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003cp\u003eFor more information regarding this service, please see - \u003cstrong\u003e\u003ca href=\"https:\/\/www.tanks-direct.co.uk\/grp-commissioning\"\u003eDoes your water tank need a clean?\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1 to 3 years\u003c\/li\u003e\n\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789760837,"sku":"PW.1X1X1.IFB.500.AG","price":1593.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/47068_23543.jpg?v=1767875687"},{"product_id":"1000-litre-grp-sectional-water-tank-internally-flanged-base-ab-airgap","title":"1000 Litre GRP Sectional Water Tank, Internally Flanged Base AB Airgap","description":"\u003ch2\u003e1000 Litre Sectional Water Tank, Internally Flanged Base (IFB) Airgap\u003c\/h2\u003e\n\n\u003cp\u003e1000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ccaption\u003e\n\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.IFB Dimensions\u003c\/p\u003e\n\n\t\u003c\/caption\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Airgap\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1150x1150x1550mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2150x2150x2050mm high\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789826373,"sku":"PW.1x1x1.IFB.AB","price":1453.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c925-3-ffabf326.jpg?v=1768235798"},{"product_id":"1000-litre-grp-sectional-water-tank-internally-flanged-base-divided-ab-airgap","title":"1000 Litre GRP Sectional Water Tank, Internally Flanged Base, Divided, AB Airgap","description":"\u003ch2\u003e1000 Litre Sectional Water Tank, Internally Flanged Base (IFB), Divided, AB Airgap\u003c\/h2\u003e\n\u003cp\u003e1000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e2 No 500x1000x1000mm compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.IFB.AB.DIV(0.5+0.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No 500x1000x1000mm compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150x1150x1550mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150x2150x2050mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789891909,"sku":"PW.1x1x1.IFB.AB.DIV(0.5+0.5)","price":1793.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c1446-2-142562a1.jpg?v=1768235520"},{"product_id":"1000-litre-grp-sectional-water-tank-internally-flanged-base-ifb-divided","title":"1000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided","description":"\u003ch2\u003e1000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided\u003c\/h2\u003e\n\u003cp\u003e1000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e2 No 500x1000x1000mm compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x1.IFB-AG.DIV (0.5+0.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No 500x1000x1000mm compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150x1150x1250mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150x2150x1750mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789924677,"sku":"PW.1x1x1.IFB-AG.DIV (0.5+0.5)","price":1518.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c1436-3-7caa7430.jpg?v=1768235496"},{"product_id":"2000-litre-grp-sectional-water-tank-1x1x2-internally-flanged-base-ifb","title":"2000 Litre GRP Sectional Water Tank, 1x1x2 Internally Flanged Base (IFB)","description":"\u003ch2\u003e2000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e2000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eTank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x2.IFB-AG Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150 x 1150 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150 x 2150 x 2750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703789990213,"sku":"PW.1x1x2.IFB","price":1846.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36620_18941.jpg?v=1767875688"},{"product_id":"2000-litre-grp-sectional-water-tank-1x1x2-internally-flanged-base-ab-airgap-ifb","title":"2000 Litre GRP Sectional Water Tank, 1x1x2 Internally Flanged Base, AB Airgap (IFB)","description":"\u003ch2\u003e2000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e2000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.1x1x2.IFB-AB Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1150 x 1150 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150 x 2150 x 3050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790022981,"sku":"PW.1x1x2.IFB-AB","price":1892.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36623_18942.jpg?v=1767875689"},{"product_id":"7500-litre-grp-sectional-water-tank-internally-flanged-base-ifb","title":"7500 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB)","description":"\u003ch2\u003e7500 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e7500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1500 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x1.5.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2950 x 2450 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3950 x 3450 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790088517,"sku":"PW.2.5x2x1.5.IFB","price":4320.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36538_18932.jpg?v=1767875688"},{"product_id":"7500-litre-grp-sectional-water-tank-2-5x2x1-5-internally-flanged-base-divided-ab-airgap","title":"7500 Litre GRP Sectional Water Tank, 2.5x2x1.5 Internally Flanged Base, Divided, AB Airgap","description":"\u003ch2\u003e7500 Litre Sectional Water Tank, Internally Flanged Base (IFB), Divided, AB Airgap\u003c\/h2\u003e\n\u003ch3\u003e7500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/h3\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e2 x 1x1x1 high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x1.5.IFB.AB.DIV(1+1) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No. 2500 x 1000 x 1500 mm Compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2450 x 2050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3650 x 3450 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790121285,"sku":"PW.2.5x2x1.5.IFB-AB.DIV(1+1)","price":6078.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/42041_19612.jpg?v=1767875688"},{"product_id":"5000-litre-grp-sectional-water-tank-internally-flanged-base-ifb","title":"5000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB)","description":"\u003ch2\u003e5000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e5000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x.1.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2150 x 1250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3650 x 3150 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790154053,"sku":"PW.2.5x2x1.IFB","price":3406.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/4211_18877.jpg?v=1767875689"},{"product_id":"5000-litre-grp-sectional-water-tank-internally-flanged-base-divided-ab-airgap","title":"5000 Litre GRP Sectional Water Tank, Internally Flanged Base, Divided, AB Airgap","description":"\u003ch2\u003e5000 Litre Sectional Water Tank, Internally Flanged Base (IFB), Divided, AB Airgap\u003c\/h2\u003e\n\u003ch3\u003e5000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/h3\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e2 x 1x1x1 high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x1.IFB.AB.DIV(1+1) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No. 2500 x 1000 x 1000 mm Compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2150 x 1550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3650 x 3150 x 2050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790219589,"sku":"PW.2.5x2x1.IFB-AB.DIV(1+1)","price":4897.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/41969_19605.jpg?v=1767875688"},{"product_id":"5000-litre-grp-sectional-water-tank-internally-flanged-base-ifb-divided","title":"5000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided","description":"\u003ch2\u003e5000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided\u003c\/h2\u003e\n\u003cp\u003e5000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e2.5x1x1 high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x1.IFB-AG.DIV (0.5+0.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No. 2500 x 1000 x 1000 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2150 x 1250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3650 x 3150 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790285125,"sku":"PW.2.5x2x1.IFB-AG.DIV (1+1)","price":4114.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/38092_19126.jpg?v=1767875688"},{"product_id":"10000-litre-grp-sectional-water-tank-2-5x2x2-internally-flanged-base-ifb","title":"10000 Litre GRP Sectional Water Tank, 2.5x2x2 Internally Flanged Base (IFB)","description":"\u003ch2\u003e10000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e10000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x2.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions (L x W x H)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2950 x 2450 x 2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3950 x 3450 x 2750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790317893,"sku":"PW.2.5x2x2.IFB","price":4913.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/4212_18968.jpg?v=1767875688"},{"product_id":"10000-litre-grp-sectional-2-5x2x2-water-tank-internally-flanged-base-divided-ab-airgap","title":"10000 Litre GRP Sectional 2.5x2x2 Water Tank, Internally Flanged Base, Divided, AB Airgap","description":"\u003ch2\u003e10000 Litre Sectional Water Tank, Internally Flanged Base (IFB), Divided, AB Airgap\u003c\/h2\u003e\n\u003cp\u003e10000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e1x1x1 \u0026amp; 0.5x1x1m high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x2.IFB.AB.DIV(1+1) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - No. 2500 x 1000 x 2000 mm high compartments\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2650 x 2450 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3650 x 3450 x 3050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790350661,"sku":"PW.2.5x2x2.IFB.AB.DIV(1+1)","price":7032.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/42051_19647.jpg?v=1767875688"},{"product_id":"10000-litre-grp-sectional-water-tank-2-5x2x2-internally-flanged-base-ab-airgap-ifb","title":"10000 Litre GRP Sectional Water Tank, 2.5x2x2 Internally Flanged Base, AB Airgap (IFB)","description":"\u003ch2\u003e10000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e10000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2.5x2x2.IFB-AB Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2950 x 2450 x 2550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3950 x 3450 x 3050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790416197,"sku":"PW.2.5x2x2.IFB-AB","price":5350.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36888_18967.jpg?v=1767875689"},{"product_id":"4500-litre-grp-sectional-water-tank-internally-flanged-base-ifb","title":"4500 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB)","description":"\u003ch2\u003e4500 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e4500 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eImportant:\u003c\/em\u003e All water storage tanks supplying water to a portable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eManway: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2x1.5x1.5.IFB Dimension\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2450 x 1950 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3450 x 2950 x2250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790448965,"sku":"PW.2x1.5x1.5.IFB","price":3129.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36359_18899.jpg?v=1767875688"},{"product_id":"5853-litre-grp-sectional-water-tank-totally-internally-flanged-tif","title":"5853 Litre GRP Sectional Water Tank, Totally Internally Flanged (TIF)","description":"\u003ch2\u003e5853 Litre Sectional Water Tank, Totally Internally Flanged (TIF)\u003c\/h2\u003e\n\u003cp\u003e5853 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and internally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eTIF tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eTIF tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eImportant:\u003c\/em\u003e All water storage tanks supplying water to a portable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eA Totally Internally Flanged Tank (TIF) is one of the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, internally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 38 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eFixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eManway: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2x1.5x1.5.TIF Dimension\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Nominal Capacity\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e5853 Litres\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2250 x 1750 x 1900 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e50 mm to 3 sides, 600 mm to one face - Height Required 2400 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790514501,"sku":"PW.2x1.5x1.5.TIF","price":6158.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/46157_22414.jpg?v=1767875689"},{"product_id":"5853-litre-grp-sectional-water-tank-totally-internally-flanged-tifb-divided","title":"5853 Litre GRP Sectional Water Tank, Totally Internally Flanged (TIFB) Divided","description":"\u003ch2\u003e5853 Litre GRP Sectional Water Tank, Totally Internally Flanged (TIF) Divided\u003c\/h2\u003e\n\u003cp\u003e5853 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and internally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eTIF tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eTIF tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eA Totally Internally Flanged Tank (TIF) is one of the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, internally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 38 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eFixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e1 x 1.5 x 1.5 m high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2x1.5x1.5.TIF-AG.DIV (1+1) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Airgap\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Nominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e5853 Litres\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Single or twin compartment (Divided)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No. 1000 x 1500 x 1500 mm \u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e External Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2250 x 1750 x 1900 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e\u003cstrong\u003e Assembly area required\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e50 mm to 3 sides, 600 mm to one face - Height Required 2400 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790547269,"sku":"PW.2x1.5x1.5.TIF-AG.DIV (1+1)","price":7240.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/46159_22418.jpg?v=1767875690"},{"product_id":"3000-litre-grp-sectional-water-tank-2x1-5x1-internally-flanged-base-ifb","title":"3000 Litre GRP Sectional Water Tank, 2x1.5x1 Internally Flanged Base (IFB)","description":"\u003ch2\u003e3000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e3000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly. Comes with man way access\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 25 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2x1.5x1.IFB Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or Twin Compartment (divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e 2150 x 1650 x 1250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly Area Required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3150 x 2650 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your Water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790612805,"sku":"PW.2x1.5x1.IFB","price":2569.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36228_18873.jpg?v=1767875689"},{"product_id":"3000-litre-grp-sectional-water-tank-2x1-5x1-internally-flanged-base-ab-airgap-ifb","title":"3000 Litre GRP Sectional Water Tank, 2x1.5x1 Internally Flanged Base, AB Airgap (IFB)","description":"\u003ch2\u003e3000 Litre Sectional Water Tank, Internally Flanged Base (IFB)\u003c\/h2\u003e\n\u003cp\u003e3000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.2x1.5x1.IFB-AB Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2150 x 1650 x 1550 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3150 x 2650 x 2050 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790645573,"sku":"PW.2x1.5x1.IFB-AB","price":2877.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/36229_18874.jpg?v=1767875690"},{"product_id":"3000-litre-grp-sectional-water-tank-internally-flanged-base-ifb-divided","title":"3000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided","description":"\u003ch2\u003e3000 Litre GRP Sectional Water Tank, Internally Flanged Base (IFB) Divided\u003c\/h2\u003e\n\u003cp\u003e3000 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and externally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003ch3\u003eWhat's the Divided Section for in a sectional tank?\u003c\/h3\u003e\n\u003cp\u003eTanks with an internal division, which is also known as a maintenance division, are suitable for buildings that we require an uninterrupted water supply during periods of maintenance to the tank. The internal divider creates two isolated compartments within a single tank, which enables one side of the tank to be taken out of service for maintenance, whilst water supply is maintained to the building via the second compartment of the tank.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlease note: divided tanks are essentially two separate tanks \u0026amp; therefore require double the quantity of connections, i.e. 2 x inlet connections \u0026amp; 2 x outlet connections to the down services. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eIFB tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eIFB tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cp\u003eScreened lid vent\u003cbr\u003eScreened overflow ¾' (22 mm) up to 4\" \u003cbr\u003eScreened warning pipe ¾' (22 mm)\u003cbr\u003eBSP female tank connector 1\" up to 4\" \u003cbr\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/p\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eAn Internally Flanged Base Tank (IFB) is the most cost-effective sectional tank format and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, externally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 50 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Externally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eInternal fixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eExternal fixings: Galvanised\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003e1.5x1x1 high compartments (divided sections)\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003ePW.3x1x1.IFB-AG.DIV (1.5+1.5) Dimensions\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e AG\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eTwin - 2 No. 1500 x 1000 x 1000 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3150 x 1150 x 1250 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e4150 x 2150 x 1750 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1-3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790711109,"sku":"PW.3x1x1.IFB-AG.DIV (1.5+1.5)","price":2980.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/38404_19154.jpg?v=1767875688"},{"product_id":"4079-litre-grp-sectional-water-tank-2x1-5x1-totally-internally-flanged-ab-airgap-tif","title":"4079 Litre GRP Sectional Water Tank, 2x1.5x1 Totally Internally Flanged, AB Airgap (TIF)","description":"\u003ch2\u003e4079 Litre Sectional Water Tank, Totally Internally Flanged (TIF) AB Airgap\u003c\/h2\u003e\n\u003cp\u003e4079 Litre GRP Sectional Water Tank, a sectional tank with an internally flanged base and Internally flanged sides. Modular construction utilising bolt together panels suitable for on-site assembly.\u003c\/p\u003e\n\u003cp\u003eInsulated and WRAS approved for use with potable water. Suitable for a variety of applications including process cooling, rainwater harvesting and many other systems and processes where containment of water is necessary. All gaskets, seals and fixings for assembly are included. Available for self-assembly, or on site assembly is available by qualified engineers for an additional cost.\u003c\/p\u003e\n\u003cp\u003eTIF tanks are suitable for positioning onto a flat, level and continuous foundation, normally a structural concrete slab. \u003c\/p\u003e\n\u003cp\u003eTIF tanks require a minimum of 500 mm working clearance all around the tank, a minimum of 500 mm above the man-way height and\/or 350 mm above any raised float valve housing. \u003c\/p\u003e\n\u003ch3\u003eOptional Extras:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eScreened lid vent\u003c\/li\u003e\n\t\u003cli\u003eScreened overflow ¾'' (22 mm) up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eScreened warning pipe ¾'' (22 mm)\u003c\/li\u003e\n\t\u003cli\u003eBSP female tank connector 1\" up to 4\" \u003c\/li\u003e\n\t\u003cli\u003eLid mounted level switch to suit high or low warning Temperature sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImportant: All water storage tanks supplying water to a potable system require pre-commission cleaning and sterilisation, we can also carry out this work and issue the appropriate certificates. \u003c\/p\u003e\n\u003cp\u003eA Totally Internally Flanged Tank (TIF) is one of the most cost-effective sectional tank formats and is suitable for: Positioning onto a flat, solid, level and continuous foundation.\u003c\/p\u003e\n\u003cp\u003eApplications where there is sufficient working room all around the tank.\u003c\/p\u003e\n\u003cp\u003eComprising: Internally flanged base, internally flanged sides, internally flanged roof. \u003c\/p\u003e\n\u003cp\u003eInsulated to the sides and cover only.\u003c\/p\u003e\n\u003ch3\u003eSpecification:\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eInsulation: 38 mm Fully Encapsulated to Sides\u003c\/li\u003e\n\t\u003cli\u003ePanel Size: 1000 x 1000 mm\u003c\/li\u003e\n\t\u003cli\u003eSide Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eBase Panels: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eHeavy Duty Lid: Internally Flanged\u003c\/li\u003e\n\t\u003cli\u003eFixings: Stainless Steel\u003c\/li\u003e\n\t\u003cli\u003eMan way: Included, providing 800 x 800 mm access opening\u003c\/li\u003e\n\t\u003cli\u003eFoundation Levelling Steels: Included (To suit flat structural foundation pad)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp\u003ePW.2x1.5x1.TIF-AB Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e Airgap\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eAB\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e Nominal Capacity\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e4079 Litres\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e Single or twin compartment (Divided)\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eSingle\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e External Dimensions\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2250 x 1750 x 1725 mm high\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e Assembly area required\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e50 mm to 3 sides, 600 mm to one face - Height Required 2075 mm\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDoes your water tank need a clean?\u003c\/h3\u003e\n\u003cp\u003eWater can pose a number of risks if not maintained correctly, with this in mind we can offer the below service for your GRP tanks.\u003c\/p\u003e\n\u003ch3\u003eAnnual Disinfection Information and Options\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eWe can offer monthly, yearly and fixed priced packages ranging from 1–3 years\u003c\/li\u003e\n\t\u003cli\u003eAll work is carried out by CSCS qualified engineers\u003c\/li\u003e\n\t\u003cli\u003eTank upgrade works available, bringing the old tanks up to current regulations\u003c\/li\u003e\n\t\u003cli\u003eFull tank replacement works available\u003c\/li\u003e\n\t\u003cli\u003eLegionella risk assessments including schematic drawings if required\u003c\/li\u003e\n\t\u003cli\u003eMicrobiology analysis - water sampling via UKAS approved laboratories\u003c\/li\u003e\n\t\u003cli\u003eBuilding flush and mains injection\u003c\/li\u003e\n\t\u003cli\u003eCommissioning of booster sets\u003c\/li\u003e\n\t\u003cli\u003eServicing of water softeners and booster sets\u003c\/li\u003e\n\t\u003cli\u003eReplacement of hollow roof struts.\u003c\/li\u003e\n\t\u003cli\u003eInsulating of existing cold water storage tanks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eAll our GRP Sectional tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703790743877,"sku":"PW.2x1.5x1.TIF-AB","price":5191.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/46043_22235.jpg?v=1767875689"}],"url":"https:\/\/tanks-direct.co.uk\/collections\/glass-reinforced-plastic-tanks.oembed?page=2","provider":"Tanks Direct","version":"1.0","type":"link"}