{"title":"Full Retention Separators","description":"","products":[{"product_id":"klargester-full-retention-separator-nsfa015-835ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA015 - 835MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFA015 Full Retention Separator for 835m² drainage area\u003c\/h2\u003e\n\n\u003cp\u003eThe Kingspan Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\n\u003ch3\u003eFull Retention Separator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eCertified to EN858 - 1 for complete peace of mind\u003c\/li\u003e\n\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1)\u003c\/li\u003e\n\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\n\t\u003cli\u003ePE and GRP model construction - high strength and durability\u003c\/li\u003e\n\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003ePerformance and compliance\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003eKingspan were one of the first UK manufacturers to have full retention separators certified to the EN 858–1 standards within the UK\u003c\/li\u003e\n\n\t\u003cli\u003eThe NSF number denotes the flow in which the separator operates\u003c\/li\u003e\n\n\t\u003cli\u003eApproved by the British Standards Institute (BSI) in relation to flow and process performance, meeting effluent quality requirements of EN 858-1\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align:left\"\u003eNSFA015 Technical Specifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: NSFA015\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eMaterial: \u003c\/strong\u003eGRP Chamber Construction\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eFlow (l\/s): \u003c\/strong\u003e15\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018): \u003c\/strong\u003e835\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eStorage Capacity (L) Silt: \u003c\/strong\u003e1500\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eStorage Capacity (L) Oil: \u003c\/strong\u003e150\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eLength (mm): \u003c\/strong\u003e3910\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eDiameter (mm): \u003c\/strong\u003e1225\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eManhole Cover Dimensions (mm): \u003c\/strong\u003e600\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eBase Inlet Invert (mm): \u003c\/strong\u003e1050\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eBase Outlet Invert (mm): \u003c\/strong\u003e1000\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eMin Inlet Invert (mm): \u003c\/strong\u003e1000\u003c\/li\u003e\n\n\t\u003cli style=\"text-align: left;\"\u003e\n\u003cstrong\u003eStandard Pipework Diameter (mm): \u003c\/strong\u003e200\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703783862597,"sku":"NSFA0151ADAK","price":2188.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3988_25729.jpg?v=1767875795"},{"product_id":"klargester-full-retention-separator-nsfa020-1115ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA020 - 1115MÂ² drainage area","description":"\u003ch2\u003eKlargester Full Retention Separator for 1115m² drainage area\u003c\/h2\u003e\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\u003ch3\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003cbr\u003eFull Retention Separator Features\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003c\/li\u003e\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\t\u003cli\u003ePE and GRP model construction - high strength and durability\u003c\/li\u003e\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNSFA020 Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eModel: \u003c\/strong\u003eNSFA020\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMaterial: \u003c\/strong\u003eGRP Chamber Construction\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eFlow (l\/s):\u003c\/strong\u003e 20\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018):\u003c\/strong\u003e 1115\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Silt:\u003c\/strong\u003e 2000\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Oil: \u003c\/strong\u003e200\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eLength (mm): \u003c\/strong\u003e3200\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDiameter (mm):\u003c\/strong\u003e 2010\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eManhole cover Dimensions (mm):\u003c\/strong\u003e 600\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBase Inlet Invert (mm): \u003c\/strong\u003e1810\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBase to Outlet Invert (mm):\u003c\/strong\u003e 1760\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMin Inlet Invert (mm): \u003c\/strong\u003e1000\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eStandard Pipework Diameter (mm):\u003c\/strong\u003e 315\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703783895365,"sku":"NSFA0201AGAK","price":3437.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3989_17652.jpg?v=1767800065"},{"product_id":"klargester-full-retention-separator-nsfa030-1670ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA030 - 1670MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFA030 Full Retention Separator for 1670m² drainage area\u003c\/h2\u003e\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003cbr\u003eFull Retention Separator Features\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003c\/li\u003e\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\t\u003cli\u003ePE and GRP model construction - high strength and durability\u003c\/li\u003e\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:1250px\"\u003e\n\t\u003ccaption\u003e\n\t\u003cp style=\"text-align:left\"\u003eNSFA030 Technical Specifications\u003c\/p\u003e\n\t\u003c\/caption\u003e\n\t\u003ctbody\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eFlow (l\/s)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eStorage Capacity (L) Silt\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eStorage Capacity (L) Oil\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eLength (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eDiameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eManhole Cover Dimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eBase Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eBase to Outlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eMin Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e\u003cstrong\u003eStandard Pipework Diameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n \u003c\/tr\u003e\n \u003ctr\u003e\n \u003ctd style=\"text-align:center\"\u003eNSFA030\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003eGRP Chamber Construction\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e30\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1670\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3000\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e300\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e3915\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e2010\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e600\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1810\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1760\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e1000\u003c\/td\u003e\n \u003ctd style=\"text-align:center\"\u003e315\u003c\/td\u003e\n \u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703783928133,"sku":"NSFA0301AGAK","price":4045.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3990_17658.jpg?v=1767800066"},{"product_id":"klargester-full-retention-separator-nsfa040-2225ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA040 - 2225MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFA040 Full Retention Separator for 2225m² drainage area\u003c\/h2\u003e\n\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003cbr\u003e\nFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\n\u003ch3\u003e\n\nFull Retention Separator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003c\/li\u003e\n\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\n\t\u003cli\u003eGRP model construction - high strength and durability\u003c\/li\u003e\n\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eEach full retention Separator design includes the necessary volume requirements for:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eOil Separation capacity\u003c\/li\u003e\n\n\t\u003cli\u003eOil Storage volume\u003c\/li\u003e\n\n\t\u003cli\u003eSilt Storage capacity\u003c\/li\u003e\n\n\t\u003cli\u003eCoalescer\u003c\/li\u003e\n\n\t\u003cli\u003eAutomatic Closure Device\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eNSFA040 Technical Specifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e NSFA040\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eMaterial: \u003c\/strong\u003eGRP Chamber Construction\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eFlow (l\/s):\u003c\/strong\u003e 40\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018)\u003c\/strong\u003e: 2225\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Silt:\u003c\/strong\u003e 4000\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Oil: \u003c\/strong\u003e400\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eLength (mm): \u003c\/strong\u003e4640\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eDiameter (mm):\u003c\/strong\u003e 2010\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eManhole Cover Dimensions (mm):\u003c\/strong\u003e 600\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eBase Inlet Invert (mm): \u003c\/strong\u003e1810\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eBase to Outlet Invert (mm): \u003c\/strong\u003e1760\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eMin Inlet Invert (mm):\u003c\/strong\u003e 1000\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eStandard Pipework Diameter (mm):\u003c\/strong\u003e 315\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703783960901,"sku":"NSFA0401AGAK","price":5059.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3991_17659.jpg?v=1767800068"},{"product_id":"klargester-full-retention-separator-nsfa050-2780ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA050 - 2780MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFA050 Full Retention Separator for 2780m² drainage area\u003c\/h2\u003e\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003cbr\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003cbr\u003eFull Retention Separator Features\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003c\/li\u003e\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\t\u003cli\u003eGRP model construction - high strength and durability\u003c\/li\u003e\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNSFA050 Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eModel: \u003c\/strong\u003eNSFA050\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMaterial: \u003c\/strong\u003eGRP Chamber Construction\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eFlow (l\/s): \u003c\/strong\u003e50\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018): \u003c\/strong\u003e2780\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Silt: \u003c\/strong\u003e5000\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Oil:\u003c\/strong\u003e 500\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eLength (mm): \u003c\/strong\u003e5425\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDiameter (mm): \u003c\/strong\u003e2010\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eManhole Cover Dimensions (mm): \u003c\/strong\u003e600\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBase Inlet Invert (mm): \u003c\/strong\u003e1810\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eBase to Outlet Invert (mm): \u003c\/strong\u003e1760\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMin Inlet Invert (mm): \u003c\/strong\u003e1000\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eStandard Pipework Diameter (mm): \u003c\/strong\u003e315\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703784059205,"sku":"NSFA0501AGAK","price":6029.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3992_17662.jpg?v=1767800070"},{"product_id":"klargester-nsfa080-full-retention-g-orientation-315mm-inlet-outlet","title":"Klargester NSFA080 Full retention G orientation 315mm inlet\/outlet","description":"","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703784124741,"sku":"NSFA0801GGBK","price":10486.8,"currency_code":"GBP","in_stock":true}]},{"product_id":"klargester-full-retention-separator-nsfp003-170ma2-drainage-area","title":"Klargester Full Retention Separator - NSFP003 - 170MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFP003 Full Retention Separator for 170M² drainage area\u003c\/h2\u003e\n\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\n\u003ch3\u003eFull Retention Separator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1)\u003c\/li\u003e\n\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\n\t\u003cli\u003ePE and GRP model construction - high strength and durability\u003c\/li\u003e\n\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cp\u003eFull retention separators are used in high risk spillage areas such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eFuel Distribution depots\u003c\/li\u003e\n\n\t\u003cli\u003eVehicle Workshops\u003c\/li\u003e\n\n\t\u003cli\u003escrapyards\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eNSFP003 Specifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:500px\"\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Model Reference:\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e NSFP003\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\n\u003cstrong\u003e Material\u003c\/strong\u003e:\u003c\/td\u003e\n\n \u003ctd\u003e Polyethylene Chamber Construction\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Flow (l\/s):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 3\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Drainage Area (m2) PPG-3 (0.018):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 170\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\n\u003cstrong\u003e Storage Capacity (L) Silt\u003c\/strong\u003e:\u003c\/td\u003e\n\n \u003ctd\u003e 300\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Storage Capacity (L) Oil:\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 30\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Length (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 1700\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Diameter (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 1350\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Manhole Cover Dimensions (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 600\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Base Inlet Invert (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 1410\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Base Outlet Invert (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 1335\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Min Inlet Invert (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 550\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Standard Pipework Diameter (mm):\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd\u003e 160\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703784681797,"sku":"NSFP0031CAK","price":988.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3993_17650.jpg?v=1767875795"},{"product_id":"klargester-full-retention-separator-nsfp006-335ma2-drainage-area","title":"Klargester Full Retention Separator - NSFP006 - 335MÂ² drainage area","description":"\u003ch2\u003eKlargester NSFP006 Full Retention Separator for 335m2 drainage area\u003c\/h2\u003e\n\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\n\u003cp\u003eKingspan Klaregsters range of full retention separators were the first UK manufacturer to have the required 3 -30 l\/sec certified to EN 858-1 in the UK. The NSF number denotes the flow at which the separator operates.\u003c\/p\u003e\n\n\u003ch3\u003eFull Retention Separator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1)\u003c\/li\u003e\n\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\n\t\u003cli\u003ePE and GRP model construction - high strength and durability\u003c\/li\u003e\n\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cp\u003eKlargesters full retention separators are used in high risk spillage areas such as:\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eFuel Distribution depots\u003c\/li\u003e\n\n\t\u003cli\u003eVehicle workshops\u003c\/li\u003e\n\n\t\u003cli\u003eScrapyards\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eNSFP006 Specifications\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eModel Reference:\u003c\/strong\u003e NSFP006\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eMaterial\u003c\/strong\u003e: Polyethylene Chamber Construction\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eFlow (l\/s):\u003c\/strong\u003e 6\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eDrainage Area (m2) PPG-3 (0.018):\u003c\/strong\u003e 335\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Silt: \u003c\/strong\u003e600\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eStorage Capacity (L) Oil: \u003c\/strong\u003e60\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eLength (mm): \u003c\/strong\u003e1700\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eDiameter (mm):\u003c\/strong\u003e 1350\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eManhole Cover Dimensions (mm):\u003c\/strong\u003e 600\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eBase Inlet Invert (mm): \u003c\/strong\u003e1410\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eBase to Outlet invert (mm):\u003c\/strong\u003e 1335\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eMin Inlet Invert (mm):\u003c\/strong\u003e 550\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eStandard Pipework Diameter (mm): \u003c\/strong\u003e160\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703784714565,"sku":"NSFP0061CAK","price":1171.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/3994_17649.jpg?v=1767875795"},{"product_id":"klargester-full-retention-separator-nsfa065-nsfa285-up-to-15-833ma2-drainage-area","title":"Klargester Full Retention Separator - NSFA065 - NSFA285 up to 15,833MÂ² drainage area","description":"\u003ch2\u003eKlargester Full Retention Separators up to 15,833M² drainage area \u003c\/h2\u003e\n\u003cp\u003eThe Klargester NSFA065 - NSFA285 range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts and are available to cover drainage areas from 3,610M² to 15,833M² .\u003cbr\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on the Technical Specifications and Options for the NSFA065 - NSFA285 models, please contact us directly on Email: \u003ca href=\"mailto:sales@tanks-direct.co.uk\"\u003esales@tanks-direct.co.uk\u003c\/a\u003e or Sales: \u003ca href=\"tel:03332570376\"\u003e0333 257 0376\u003c\/a\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eFull Retention Separator Features\u003c\/h3\u003e\n\u003cul\u003e\n\t\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\t\u003cli\u003eCertified to EN858 - 1 and PPG3 for complete peace of mind\u003c\/li\u003e\n\t\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003c\/li\u003e\n\t\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\t\u003cli\u003eVent points within necks\u003c\/li\u003e\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\t\u003cli\u003eGRP model construction - high strength and durability\u003c\/li\u003e\n\t\u003cli\u003eCE - Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach Full Retention Separator design includes the necessary volume requirements for:\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eOil Separation capacity\u003c\/li\u003e\n\t\u003cli\u003eOil Storage volume\u003c\/li\u003e\n\t\u003cli\u003eSilt Storage capacity\u003c\/li\u003e\n\t\u003cli\u003eCoalescer\u003c\/li\u003e\n\t\u003cli\u003eAutomatic Closure Device\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56703978373445,"sku":"NSFA","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/38730_19195.jpg?v=1767800063"},{"product_id":"klargester-full-retention-separator-nsfa010-555m-drainage-area","title":"Klargester Full Retention Separator - NSFA010 - 555M² drainage area","description":"\u003ch2\u003eKlargester NSFA010 Full Retention Separator for 555m² drainage area\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Klargester range of full retention separators are suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts.\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system. This is normally equivalent to the flow generated by the rainfall intensity of 65mm\/hr. On larger sites, some short term flooding may be acceptable means of limiting the flow rate and hence the size of full retention systems.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eFull Retention Separator Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for easy installation, saving time and money\u003c\/li\u003e\n\u003cli\u003eCertified to EN858 - 1 for complete peace of mind\u003c\/li\u003e\n\u003cli\u003eOil alarm probe tube available (required by EN858-1)\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eGRP model construction - high strength and durability\u003c\/li\u003e\n\u003cli\u003eCE - Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ccaption\u003e\n\u003cbr\u003e\n\u003ch3\u003eNSFA010 Specifications\u003c\/h3\u003e\n\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow (l\/s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDrainage Area (m²) PPG-3 (0.018)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Capacity (L) Silt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Capacity (L) Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLength (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBase to Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBase to Outlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMin. Inlet Inlet (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Pipework Diameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNSFA010\u003c\/td\u003e\n\u003ctd\u003eGRP Chamber Construction\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e555\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e2610\u003c\/td\u003e\n\u003ctd\u003e1225\u003c\/td\u003e\n\u003ctd\u003e1050\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts.  Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\u003cp\u003eKingspan Klargester Full Retention Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":58636472615237,"sku":"NSFA0101ADAK","price":1895.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/NSFA010.png?v=1784629481"}],"url":"https:\/\/tanks-direct.co.uk\/collections\/full-retention-separators.oembed","provider":"Tanks Direct","version":"1.0","type":"link"}