{"title":"Forecourt Separators","description":"","products":[{"product_id":"klargester-forecourt-separator","title":"Klargester Forecourt Separator","description":"\u003ch2\u003eKlargester Forecourt Separator - 10,000 Litres\u003c\/h2\u003e\n\n\u003cp\u003eThe Klargester forecourt separator is a high-performance, full retention separator engineered specially for use in areas at risk of hydrocarbon contamination, such as petrol station forecourts, vehicle workshops, commercial yards, and industrial estates. Manufactured in the UK by \u003cstrong\u003eKingspan Klargester\u003c\/strong\u003e, a leading name in environmental compliance solutions, this system is designed to intercept and retail oil, fuel and silt-laden surface water before it enters the surface drainage system.\u003c\/p\u003e\n\n\u003cp\u003eBuilt to comply with the most stringent UK regulations, including the Environment Agency's PPG3 guidelines and \u003cstrong\u003eBS EN 858–1 standards\u003c\/strong\u003e, the FS010 ensures your site meets pollution prevention obligations while delivering ease of maintenance and dependable performance.\u003c\/p\u003e\n\n\u003cp\u003eOperation ensures that the flow cannot exit the unit without first passing through the coalescer assembly. In normal operation, the forecourt separator has sufficient capacity to provide storage for separated pollutants within the main chamber, but is also able to contact up to 7,600 Litres of pollutant arising from the spillage of a fuel delivery tanker compartment on the petrol forecourt. The separator has been designed to ensure that oil cannot exit the separator in the event of a major spillage, subsequently the separator should be emptied immediately.\u003c\/p\u003e\n\n\u003ch3\u003eKey Benefits\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eFull Retention Design\u003c\/strong\u003e: Captures all surface water run-off and hydrocarbon pollutants - even in the event of a major spill or storm.\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003ePollution Prevention Guarantee: \u003c\/strong\u003ePrevents oils, fuels and suspended solids from entering drains, watercourses or the wider environment.\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eFully Compliant:\u003c\/strong\u003e Meets BS EN 858–1 standards and PPG3 requirements for high risk sites\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eTough \u0026amp; Durable:\u003c\/strong\u003e Manufactured from corrosion-resistant Glass Reinforced Plastic (GRP) for long-term underground use\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eLow Maintenance Operation:\u003c\/strong\u003e Integral silt chamber and coalescer extend servicing intervals\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eAutomatic Closure Device (ACD):\u003c\/strong\u003e Shuts off flow in the event of a sudden fuel release - standard on all forecourt models.\u003c\/li\u003e\n\n\t\u003cli\u003e\n\u003cstrong\u003eSimple Access for Servicing: \u003c\/strong\u003eLockable inspection covers ensure easy, safe maintenance.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eForecourt Separator Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eLight and easy to install\u003c\/li\u003e\n\n\t\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\n\t\u003cli\u003eFitted inlet\/ outlet connectors\u003c\/li\u003e\n\n\t\u003cli\u003eVent points within necks Extension access shafts for deep inverts\u003c\/li\u003e\n\n\t\u003cli\u003eAvailable with 160mm or 200mm inlet\/outlet pipework options\u003c\/li\u003e\n\n\t\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\n\t\u003cli\u003eOil storage volume.\u003c\/li\u003e\n\n\t\u003cli\u003eCoalescer \u003c\/li\u003e\n\n\t\u003cli\u003eAutomatic closure device\u003c\/li\u003e\n\n\t\u003cli\u003eOil alarm system available\u003c\/li\u003e\n\n\t\u003cli\u003eCE - marked\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eForecourt Separator Specifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"wiIXO-DTh:750px\"\u003e\n\n\t\u003ctbody\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Class\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eI\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eI\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Backfill Type\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eConcrete\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003eConcrete\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Total Capacity (L)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e10000\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e10000\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Drainage Area (m2)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e835\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e1115\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Peak Flow Rate (l\/s)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e15\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e20\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Length (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e3915\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e3915\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Diameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2020\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2020\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Access Shaft Diameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e600\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e600\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Base Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2180\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2180\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n \u003ctr\u003e\n\n \u003ctd style=\"background-color:#addfff\"\u003e\u003cstrong\u003e Base to Outlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2130\u003c\/td\u003e\n\n \u003ctd style=\"text-align:center\"\u003e2130\u003c\/td\u003e\n\n \u003c\/tr\u003e\n\n\t\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003eGarage Forecourts\u003c\/li\u003e\n\n\t\u003cli\u003eCar Parks\u003c\/li\u003e\n\n\t\u003cli\u003eWorkshops\u003c\/li\u003e\n\n\t\u003cli\u003eSupermarket \/ Shopping Centres\u003c\/li\u003e\n\n\t\u003cli\u003eDistribution Warehouses\u003c\/li\u003e\n\n\t\u003cli\u003eCar Wash Bays\u003c\/li\u003e\n\n\t\u003cli\u003eScrapyards\u003c\/li\u003e\n\n\t\u003cli\u003eCar Garages\u003c\/li\u003e\n\n\t\u003cli\u003eFuel Storage Sites\u003c\/li\u003e\n\n\t\u003cli\u003eDistribution \/ Haulage Centres\u003c\/li\u003e\n\n\t\u003cli\u003eWaste Transfer Sites\u003c\/li\u003e\n\n\t\u003cli\u003eBusiness, Commercial parks and Industrial Estates\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eBritish European Standard EN 858-1. It should be installed and calibrated by a suitably qualified technician so that it will respond to an alarm condition when the separator requires emptying.\u003c\/p\u003e\n\n\u003ch3\u003eAvailable with Smart Commissioning \u003c\/h3\u003e\n\n\u003cp\u003eStandard commissioning as scope of works, inc supplied and fitted (at point of commissioning) Kingspan Smartserv Pro GSM telemetry alarm for complete peace of mind. \u003c\/p\u003e\n\n\u003cp\u003eSmartserv alerts both Kingspan and designated contacts. Includes 3 years Kingspan monitoring free of charge.*\u003c\/p\u003e\n\n\u003cp\u003e*Kingspan monitoring is for alert only. \u003c\/p\u003e\n\n\u003cp\u003eService\/maintenance packages are available at separate cost on request.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eOur Forecourt Separators are delivered on a Flat bed Arctic lorry, however they require offloading by the customer. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle) delivery is available at an additional cost. Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"160mm Pipework","offer_id":56926788682053,"sku":"FS010104IE","price":3599.0,"currency_code":"GBP","in_stock":true},{"title":"200mm Pipework","offer_id":56926788714821,"sku":"FS010104K","price":3599.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2852_25721.jpg?v=1778768865"}],"url":"https:\/\/tanks-direct.co.uk\/collections\/forecourt-separators.oembed","provider":"Tanks Direct","version":"1.0","type":"link"}