{"title":"AG Air Gap GRP Combination Unit","description":"","products":[{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"3000 Litre GRP Pump Enclosure with built in Tank,  AG air gap","description":"\u003ch2\u003e3000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e \u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e**Images are for illustration purposes only\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745458501,"sku":"CU2.3000AG","price":9072.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2368_24837.jpg?v=1767875771"},{"product_id":"500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1000-500","title":"500 Litre GRP Pump Enclosure with built in Tank, AG air gap 1000-500","description":"\u003ch2\u003e500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 800 x 800 mm single hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift truck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 800 x 800 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003e**Pictures are for illustration purposes only\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745655109,"sku":"CUCOMP.1000-500","price":2156.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45580_21251.jpg?v=1767875772"},{"product_id":"8000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-12000-8000","title":"8000 Litre GRP Pump Enclosure with built in Tank, AG air gap 12000-8000","description":"\u003ch2\u003e8000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745687877,"sku":"CUCOMP.12000-8000","price":13910.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45667_21442.jpg?v=1767875772"},{"product_id":"1000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1500-1000","title":"1000 Litre GRP Pump Enclosure with built in Tank, AG air gap 1500-1000","description":"\u003ch2\u003e1000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703745786181,"sku":"CUCOMP.1500-1000","price":2581.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45621_21338.jpg?v=1767875771"},{"product_id":"500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1500-500","title":"500 Litre GRP Pump Enclosure with built in Tank, AG air gap 1500-500","description":"\u003ch2\u003e500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 22 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746539845,"sku":"CUCOMP.1500-500","price":2560.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45591_21331.jpg?v=1767875771"},{"product_id":"750-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-1500-750","title":"750 Litre GRP Pump Enclosure with built in Tank, AG air gap 1500-750","description":"\u003ch2\u003e750 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746572613,"sku":"CUCOMP.1500-750","price":2570.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45593_21332.jpg?v=1767875771"},{"product_id":"1500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3001-1500","title":"1500 Litre GRP Pump Enclosure with built in Tank, AG air gap 3001-1500","description":"\u003ch2\u003e1500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746638149,"sku":"CUCOMP.3001-1500","price":4269.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45636_21377.jpg?v=1767875772"},{"product_id":"2143-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3636-2143","title":"2143 Litre GRP Pump Enclosure with built in Tank, AG air gap 3636-2143","description":"\u003ch2\u003e2143 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746703685,"sku":"CUCOMP.3636-2143","price":4626.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45638_21381.jpg?v=1767875772"},{"product_id":"3375-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-5625-3375","title":"3375 Litre GRP Pump Enclosure with built in Tank, AG air gap 5625-3375","description":"\u003ch2\u003e3375 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746736453,"sku":"CUCOMP.5625-3375","price":6760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45654_21402.jpg?v=1767875772"},{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-7500-3000","title":"3000 Litre GRP Pump Enclosure with built in Tank, AG air gap 7500-3000","description":"\u003ch2\u003e3000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746769221,"sku":"CUCOMP.7500-3000","price":7935.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45658_21406.jpg?v=1767875772"},{"product_id":"4500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-7500-4500","title":"4500 Litre GRP Pump Enclosure with built in Tank, AG air gap 7500-4500","description":"\u003ch2\u003e4500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703746834757,"sku":"CUCOMP.7500-4500","price":7935.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45655_21404.jpg?v=1767875773"},{"product_id":"1000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"1000 Litre GRP Pump Enclosure with built in Tank, AG air gap","description":"\u003ch2\u003e1000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e**Images are for Illustration purposes only\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703899861317,"sku":"CU1.1000AG","price":9275.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/circle-item-c922-1-20cbe1ae.jpg?v=1768235785"},{"product_id":"2000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"2000 Litre GRP Pump Enclosure with built in Tank,  AG air gap","description":"\u003ch2\u003e2100 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a \"plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 1500 x 1500 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment, where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003eA fully encapsulated ply base.\u003c\/p\u003e\n\n\u003cp\u003eUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703900320069,"sku":"CU2.2000AG","price":9048.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2362_24835.jpg?v=1767875739"},{"product_id":"4000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"4000 Litre GRP Pump Enclosure with built in Tank,  AG air gap","description":"\u003ch2\u003e4000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e**Images are for Illustration Purposes only\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703901499717,"sku":"CU3.4000AG","price":11985.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2374_24840.jpg?v=1767875740"},{"product_id":"5000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"5000 Litre GRP Pump Enclosure with built in Tank,  AG air gap","description":"\u003ch2\u003e5000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703901827397,"sku":"CU3.5000AG","price":12105.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2379_24841.jpg?v=1767875740"},{"product_id":"7000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap","title":"7000 Litre GRP Pump Enclosure with built in Tank,  AG air gap","description":"\u003ch2\u003e7000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003e\n\nThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003ch3\u003eAG Air gap Connection Packs - Supplied loose\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e** Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703902482757,"sku":"CU4.7000AG","price":14899.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/2384_24843.jpg?v=1767875741"},{"product_id":"4000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-12000-4000","title":"4000 Litre GRP Pump Enclosure with built in Tank, AG air gap 12000-4000","description":"\u003ch2\u003e4000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703904088389,"sku":"CUCOMP.12000-4000","price":13430.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45670_21452.jpg?v=1767875742"},{"product_id":"6000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-12000-6000","title":"6000 Litre GRP Pump Enclosure with built in Tank, AG air gap 12000-6000","description":"\u003ch2\u003e6000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703904579909,"sku":"CUCOMP.12000-6000","price":13635.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45669_21447.jpg?v=1767875743"},{"product_id":"1000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-2000-1000","title":"1000 Litre GRP Pump Enclosure with built in Tank, AG air gap 2000-1000","description":"\u003ch2\u003e1000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703906021701,"sku":"CUCOMP.2000-1000","price":3325.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45625_21357.jpg?v=1767875745"},{"product_id":"500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-cucomp-2000-500","title":"500 Litre GRP Pump Enclosure with built in Tank, AG air gap CUCOMP.2000-500","description":"\u003ch2\u003e500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 22 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703906349381,"sku":"CUCOMP.2000-500","price":3273.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45622_21340.jpg?v=1767875746"},{"product_id":"750-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-2000-750","title":"750 Litre GRP Pump Enclosure with built in Tank, AG air gap 2000-750","description":"\u003ch2\u003e750 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703906644293,"sku":"CUCOMP.2000-750","price":3299.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45624_21355.jpg?v=1767875747"},{"product_id":"1250-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-2501-1250","title":"1250 Litre GRP Pump Enclosure with built in Tank, AG air gap 2501-1250","description":"\u003ch2\u003e1250 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703907332421,"sku":"CUCOMP.2501-1250","price":3955.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45671_21458.jpg?v=1767875687"},{"product_id":"1000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3000-1000","title":"1000 Litre GRP Pump Enclosure with built in Tank, AG air gap 3000-1000","description":"\u003ch2\u003e1000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703907660101,"sku":"CUCOMP.3000-1000","price":4249.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45632_21373.jpg?v=1767875625"},{"product_id":"1500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3000-1500","title":"1500 Litre GRP Pump Enclosure with built in Tank, AG air gap 3000-1500","description":"\u003ch2\u003e1500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703908053317,"sku":"CUCOMP.3000-1500","price":4327.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45634_21375.jpg?v=1767875627"},{"product_id":"2000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-3000-2000","title":"2000 Litre GRP Pump Enclosure with built in Tank, AG air gap 3000-2000","description":"\u003ch2\u003e2000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703908446533,"sku":"CUCOMP.3000-2000","price":4405.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45635_21379.jpg?v=1767875627"},{"product_id":"2250-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-5625-2250","title":"2250 Litre GRP Pump Enclosure with built in Tank, AG air gap 5625-2250","description":"\u003ch2\u003e2250 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703909429573,"sku":"CUCOMP.5625-2250","price":6760.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45651_21399.jpg?v=1767875629"},{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-8000-3000","title":"3000 Litre GRP Pump Enclosure with built in Tank, AG air gap 8000-3000","description":"\u003ch2\u003e3000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703910641989,"sku":"CUCOMP.8000-3000","price":10155.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45662_21418.jpg?v=1767875631"},{"product_id":"4000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-8000-4000","title":"4000 Litre GRP Pump Enclosure with built in Tank, AG air gap 8000-4000","description":"\u003ch2\u003e4000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703910936901,"sku":"CUCOMP.8000-4000","price":10036.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45660_21412.jpg?v=1767875632"},{"product_id":"3000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-9000-3000","title":"3000 Litre GRP Pump Enclosure with built in Tank, AG air gap 9000.3000","description":"\u003ch2\u003e3000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703911264581,"sku":"CUCOMP.9000.3000","price":8932.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45666_21437.jpg?v=1767875633"},{"product_id":"4500-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-9000-4500","title":"4500 Litre GRP Pump Enclosure with built in Tank, AG air gap 9000.4500","description":"\u003ch2\u003e4500 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703911625029,"sku":"CUCOMP.9000.4500","price":9068.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45665_21432.jpg?v=1767875635"},{"product_id":"6000-litre-grp-pump-enclosure-with-built-in-tank-ag-air-gap-9000-6000","title":"6000 Litre GRP Pump Enclosure with built in Tank, AG air gap 9000.6000","description":"\u003ch2\u003e6000 Litre GRP Pump Enclosure with built-in Tank, AG air gap\u003c\/h2\u003e\n\n\u003cp\u003eThe unit is designed as a single piece item with an internal dividing wall at full height. One internal section being the wet compartment for the stored water, which is accessed via a lid mounted lockable man way. Beyond the internal dividing wall is the dry side where the booster set is to be positioned. The internal dividing wall has the inlet and outlet connection within it, the overflow, warning pipe and screened spill over weir terminate through the wet side wall to the outside and do not therefore normally require any additional pipework. The dry side is accessed by a large 1600 x 1600 mm hinged and lockable door, which is fitted with louvred vents to ensure adequate ventilation.\u003cbr\u003e\nIf chosen with the Foundation Skid, the whole unit is mounted and fixed to a fully welded galvanised steel skid, which allows offloading and movement on site by fork lift struck. The principle is to provide the unit to the booster set manufacturer, where the booster and associated electrical equipment can be fitted. The completed unit can then be delivered to site where once positioned it requires the simple connection of the mains pipework, outlet pipework to the services, and electrical supply, making it a 'plug and play' unit requiring minimal on-site installation.\u003c\/p\u003e\n\n\u003ch3\u003e\nAll units are fitted with the following:\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e1 No 42 mm screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e1 No single 1550 x 1550 mm door to the end face of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003e1 No lockable access man way fitted to the roof of the wet compartment where fitted.\u003c\/li\u003e\n\n\t\u003cli\u003e1 No EPDM mat to the floor of the pump compartment\u003c\/li\u003e\n\n\t\u003cli\u003eA fully encapsulated ply base.\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nUnits do not include electrical components, wiring, pump sets, control equipment, connections of any kind or internal pipework.\u003c\/p\u003e\n\n\u003cp\u003eUnits not fitted with a galvanised steel skid are suitable for positioning onto a structural pad only, which should be flat, level and continuous and be +\/- 2 mm over the surface area.\u003c\/p\u003e\n\n\u003cp\u003ePlease note, when the galvanised skid option is added the external height increases by 210 mm.\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cem\u003e**Cat 5 (AB and AG) supplied loose\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3\u003e\nAG Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w Float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AG-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eAB Air gap\u003c\/h3\u003e\n\n\u003cp\u003eIP22-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm (1 1\/4\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP28-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e28 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm (1 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP35-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e35 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm (2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP42-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e42 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e67 mm (2 1\/2\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\n\nIP50-AB-SL\u003c\/p\u003e\n\n\u003cul\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened lid vent\u003c\/li\u003e\n\n\t\u003cli\u003e50 mm equilibrium float valve c\/w drop arm and float\u003c\/li\u003e\n\n\t\u003cli\u003e80 mm (3\") screened overflow\u003c\/li\u003e\n\n\t\u003cli\u003e22 mm (3\/4\") screened warning pipe\u003c\/li\u003e\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivery\u003c\/h3\u003e\n\n\u003cp\u003eAll our GRP tanks are for delivery by customer offload. This entails the customer to acquire the right manpower and\/or machinery to help unload the tank\/s from the delivery vehicle.\u003c\/p\u003e\n\n\u003cp\u003eIf you require assistance with offloading, we may be able to offer a tail lift (lowers the tank to the ground) or HIAB (lorry with a mounted crane to winch the tank off the delivery vehicle). Please contact us if this is required for delivery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e**Images are for Illustration purposes only\u003c\/em\u003e\u003c\/p\u003e","brand":"Purewater","offers":[{"title":"Default Title","offer_id":56703911985477,"sku":"CUCOMP.9000.6000","price":9290.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/files\/45663_21427.jpg?v=1767875635"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4595\/6165\/collections\/47722_24702.jpg?v=1783945245","url":"https:\/\/tanks-direct.co.uk\/collections\/ag-air-gap-grp-combination-unit.oembed","provider":"Tanks Direct","version":"1.0","type":"link"}